HP StorageWorks 2/64 HP StorageWorks Fabric OS 5.x Fabric Watch Administrator - Page 44

Option, Effect, Input information

Page 44 highlights

Table 15 describes the 18 customization options displayed at the end of the Advanced Configuration menu. Table 15 Advanced configuration options Option Effect Input information change behavior type Changes the behavior type of a single element to either Triggered or Continuous. The change is volatile because this option is not saved to flash memory. Every time the switch is rebooted, this option is reset. The element index and the required behavior type change behavior interval Changes the behavior interval for a single element. The change is volatile because this option is not saved to flash memory. Every time the switch is rebooted, this option is reset. The element index and the required behavior interval, in seconds change threshold boundary level Changes between the factory The required threshold column default and custom threshold information. change custom unit Changes the measurement unit assigned to the monitored data values, but only affects the custom column. The required measurement unit, as a string change custom time base Changes the time base for the The required time base area, but only affects the custom column. change custom low Changes the low setting for the threshold, but only affects the custom column. The required low threshold, in the units defined by the area change custom high Changes the high setting for the threshold, but only affects the custom column. The required high threshold, in the units defined by the area change custom buffer Changes the buffer size for the The required buffer size, in the threshold, but only affects the units defined by the area custom column. apply threshold boundary changes Confirms the changes made to the threshold information. This must be done to retain the changes made. None cancel threshold boundary changes Returns the boundary information to the last confirmed state. None change threshold alarm level Changes between the factory The required event setting column default and custom event settings for the area. 44 Configuring Fabric Watch

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

44
Configuring Fabric Watch
Table 15
describes the 18 customization options displayed at the end of the Advanced Configuration
menu.
Table 15
Advanced configuration options
Option
Effect
Input information
change behavior type
Changes the behavior type of
a single element to either
Triggered or Continuous. The
change is volatile because this
option is not saved to flash
memory. Every time the switch
is rebooted, this option is
reset.
The element index and the
required behavior type
change behavior interval
Changes the behavior interval
for a single element. The
change is volatile because this
option is not saved to flash
memory. Every time the switch
is rebooted, this option is
reset.
The element index and the
required behavior interval, in
seconds
change threshold
boundary level
Changes between the factory
default and custom threshold
information.
The required threshold column
change custom unit
Changes the measurement
unit assigned to the monitored
data values, but only affects
the custom column.
The required measurement unit,
as a string
change custom time base
Changes the time base for the
area, but only affects the
custom column.
The required time base
change custom low
Changes the low setting for
the threshold, but only affects
the custom column.
The required low threshold, in the
units defined by the area
change custom high
Changes the high setting for
the threshold, but only affects
the custom column.
The required high threshold, in
the units defined by the area
change custom buffer
Changes the buffer size for the
threshold, but only affects the
custom column.
The required buffer size, in the
units defined by the area
apply threshold boundary
changes
Confirms the changes made to
the threshold information. This
must be done to retain the
changes made.
None
cancel threshold
boundary changes
Returns the boundary
information to the last
confirmed state.
None
change threshold alarm
level
Changes between the factory
default and custom event
settings for the area.
The required event setting column