HP StorageWorks 2/64 HP StorageWorks Fabric OS 5.x Fabric Watch Administrator - Page 58

HP StorageWorks, SAN Switch 2/8V, 16V, 2/16N, SAN Switch 2/32, SAN Switch 4/32, Core Switch 2/64, - 32 san switch

Page 58 highlights

NOTE: For the 4/32 SAN Switch, there is no fan default threshold because the fans are not monitored by Fabric Watch. You can use fanShow to view the 4/32 SAN Switch fan status (OK or NOT OK). However, you cannot use fwConfigure to manipulate the threshold or alarm actions against any fans. Table 17 Environment class threshold defaults Area Fan Description Default threshold settings Monitors switch fan speed in RPMs Unit: RPM Time Base: none HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N Low: 4500 High: 11000 Buffer: 3 HP StorageWorks SAN Switch 2/32 Low: 2600 High: 10000 Buffer: 3 HP StorageWorks SAN Switch 4/32 Low: 3000 High: 12000 Buffer: 3 HP StorageWorks Core Switch 2/64 Low: 2000 High: 3400 Buffer: 3 HP StorageWorks SAN Director 2/128 Low: 1600 High: 3400 Buffer: 3 Default alarm settings Changed: 0 Above: 3 Below: 3 In-Between: 1 Threshold state Informative Out_of_range Out_of_range In_range 58 Default threshold values

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

58
Default threshold values
NOTE:
For the 4/32 SAN Switch, there is no fan default threshold because the fans are not monitored
by Fabric Watch. You can use
fanShow
to view the 4/32 SAN Switch fan status (OK or NOT OK).
However, you cannot use
fwConfigure
to manipulate the threshold or alarm actions against any fans
.
Table 17
Environment class threshold defaults
Area
Description
Default threshold
settings
Default alarm
settings
Threshold
state
Fan
Monitors switch
fan speed in RPMs
Unit: RPM
Time Base: none
HP StorageWorks
SAN Switch 2/8V,
2/16V, 2/16N
Low: 4500
High: 11000
Buffer: 3
HP StorageWorks
SAN Switch 2/32
Low: 2600
High: 10000
Buffer: 3
HP StorageWorks
SAN Switch 4/32
Low: 3000
High: 12000
Buffer: 3
HP StorageWorks
Core Switch 2/64
Low: 2000
High: 3400
Buffer: 3
HP StorageWorks
SAN Director 2/128
Low: 1600
High: 3400
Buffer: 3
Changed: 0
Above: 3
Below: 3
In-Between: 1
Informative
Out_of_range
Out_of_range
In_range