HP StorageWorks 2/64 HP StorageWorks Fabric OS 5.x Fabric Watch Administrator - Page 58
HP StorageWorks, SAN Switch 2/8V, 16V, 2/16N, SAN Switch 2/32, SAN Switch 4/32, Core Switch 2/64, - 32 san switch
![]() |
View all HP StorageWorks 2/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
NOTE: For the 4/32 SAN Switch, there is no fan default threshold because the fans are not monitored by Fabric Watch. You can use fanShow to view the 4/32 SAN Switch fan status (OK or NOT OK). However, you cannot use fwConfigure to manipulate the threshold or alarm actions against any fans. Table 17 Environment class threshold defaults Area Fan Description Default threshold settings Monitors switch fan speed in RPMs Unit: RPM Time Base: none HP StorageWorks SAN Switch 2/8V, 2/16V, 2/16N Low: 4500 High: 11000 Buffer: 3 HP StorageWorks SAN Switch 2/32 Low: 2600 High: 10000 Buffer: 3 HP StorageWorks SAN Switch 4/32 Low: 3000 High: 12000 Buffer: 3 HP StorageWorks Core Switch 2/64 Low: 2000 High: 3400 Buffer: 3 HP StorageWorks SAN Director 2/128 Low: 1600 High: 3400 Buffer: 3 Default alarm settings Changed: 0 Above: 3 Below: 3 In-Between: 1 Threshold state Informative Out_of_range Out_of_range In_range 58 Default threshold values