HP StorageWorks 2/64 HP StorageWorks Fabric OS 5.x Fabric Watch Administrator - Page 61

Performance monitor class

Page 61 highlights

Table 18 Fabric Class threshold defaults (continued) Area Description Default threshold Default alarm Threshold settings settings state Zoning Changes SFP State Changes Monitors changes to currently enabled zoning configurations Unit: zone change(s) Time Base: none Low: 0 High: 0 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Monitors SFP state changes Unit: Change(s) Time Base: Low: 0 High: 0 Buffer: 0 Changed: 0 Exceeded: 0 Below: 0 Above: 0 In-between: 0 Informative Informative Informative Informative Informative Informative Informative Informative Informative Performance monitor class Table 19 provides default settings for areas in the AL_PA Performance Monitor class. Table 19 AL_PA performance monitor class threshold defaults Area Description Default Threshold Default Alarm Threshold Settings Settings State AL_PA Invalid CRCs Monitors the number of arbitrated loop physical address CRC errors Unit: error(s) Time Base: minute Low: 0 High: 60 Buffer: 0 Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Out_of_range In_range NOTE: End-to-end and AL_PA CRC counters are not supported on the HP StorageWorks SAN Switch 4/32. Table 20 provides default settings for areas in the Customer-Defined Performance Monitor class. Table 20 Customer-Defined performance monitor class threshold defaults Area Customer-Defined Filter Description Default threshold settings Monitors the number of frames that are filtered out by the port Unit: frame(s) Time Base: none Low: 0 High: 0 Buffer: 0 Default alarm Threshold settings state Changed: 0 Below: 0 Above: 0 In-Between: 0 Informative Informative Informative Informative Fabric OS 5.x Fabric Watch administrator guide 61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

Fabric OS 5.x Fabric Watch administrator guide
61
Performance monitor class
Table 19
provides default settings for areas in the AL_PA Performance Monitor class.
NOTE:
End-to-end and AL_PA CRC counters are not supported on the HP StorageWorks SAN Switch
4/32.
Table 20
provides default settings for areas in the Customer-Defined Performance Monitor class.
Zoning Changes
Monitors changes
to currently
enabled zoning
configurations
Unit: zone change(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
SFP State
Changes
Monitors SFP state
changes
Unit: Change(s)
Time Base:
Low: 0
High: 0
Buffer: 0
Changed: 0
Exceeded: 0
Below: 0
Above: 0
In-between: 0
Informative
Informative
Informative
Informative
Informative
Table 18
Fabric Class threshold defaults (continued)
Area
Description
Default threshold
settings
Default alarm
settings
Threshold
state
Table 19
AL_PA performance monitor class threshold defaults
Area
Description
Default Threshold
Settings
Default Alarm
Settings
Threshold
State
AL_PA Invalid
CRCs
Monitors the
number of
arbitrated loop
physical address
CRC errors
Unit: error(s)
Time Base: minute
Low: 0
High: 60
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Table 20
Customer-Defined performance monitor class threshold defaults
Area
Description
Default threshold
settings
Default alarm
settings
Threshold
state
Customer-Defined
Filter
Monitors the
number of
frames that are
filtered out by
the port
Unit: frame(s)
Time Base: none
Low: 0
High: 0
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative