HP StorageWorks 8/24 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 157
CDR System Messages
View all HP StorageWorks 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 157 highlights
Chapter CDR System Messages 12 CDR-1001 Message , [CDR-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable between peer ports, or that the port speed configuration does not match the capability of the SFP. Recommended Action Ensure that you are using compatible SFPs on the peer ports. Verify whether the SFPs have deteriorated or the Fibre Channel cable is faulty. Replace the SFPs or cable, if necessary. Severity ERROR CDR-1002 Message , [CDR-1002], , FFDC, ERROR, , Port chip faulted due to internal error. Probable Cause Indicates an internal error. Recommended Action For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover the system. For a non-bladed system, perform fastBoot command on the switch to recover the system. Severity ERROR CDR-1003 Message , [CDR-1003], , FFDC, CRITICAL, , , HW ASIC chip error type =0 Probable Cause Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Whenever this error occurs, restart the system at the next maintenance window. If the problem Action persists, replace the blade. Fabric OS Message Reference 87 53-1001338-01