HP StorageWorks 8/24 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 678
Swch-1011, Swch-1012, Swch-1013, Swch-1014
View all HP StorageWorks 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 678 highlights
97 SWCH-1011 Severity WARNING SWCH-1011 Message , [SWCH-1011], ,, WARNING, , HA state out of sync: Standby CP (ver = ) does not support Trunk Area functionality. (active ver = , Trunk Area enabled on switch = ). Probable Cause Indicates the standby control processor (CP) does not support Trunk Area functionality, but the switch has some ports with Trunk Area enabled. Recommended Load a firmware version on standby that supports Trunk Area functionality, using the Action firmwareDownload command. Severity WARNING SWCH-1012 Message , [SWCH-1012], ,, INFO, , Trunk Area () has been enabled for one or more ports). Probable Cause Indicates that a Trunk Area has been enabled for one or more ports and the configuration file has been updated. Recommended No action is required. Action Severity INFO SWCH-1013 Message , [SWCH-1013], ,, INFO, , Trunk Area has been disabled for one or more ports. Probable Cause Indicates that a Trunk Area assignment has been disabled for one or more ports and the configuration file has been updated. Recommended No action is required. Action Severity INFO SWCH-1014 Message Probable Cause , [SWCH-1014], ,, INFO, , All Trunk Areas have been disabled. Indicates that all Trunk Areas have been disabled and the configuration file has been updated. 608 Fabric OS Message Reference 53-1001338-01