HP StorageWorks 8/24 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 549
RAS System Messages
View all HP StorageWorks 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 549 highlights
Chapter RAS System Messages 82 RAS-1001 Message , [RAS-1001], ,, INFO, , First failure data capture (FFDC) event occurred. Probable Cause Indicates that a failure data event was captured. Recommended Run the supportFtp command (as needed) to set up automatic FTP transfers and run the Action supportSave command then contact your switch service provider. Severity INFO RAS-1002 Message , [RAS-1002], ,, WARNING, , First failure data capture (FFDC) maximum storage size ( MB) was reached. Probable Cause Indicates that the maximum storage size for FFDC data capture is reached. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1004 Message , [RAS-1004], , FFDC, WARNING, , Software 'verify' error detected. Probable Cause Indicates an internal software error. Recommended Run the supportSave command and contact your switch service provider. Action Severity WARNING RAS-1005 Message , [RAS-1005], , FFDC, WARNING, , Software 'assert' error detected. Fabric OS Message Reference 479 53-1001338-01