HP StorageWorks 8/24 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 276
FCR-1005, FCR-1006, FCR-1007, FCR-1008
View all HP StorageWorks 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 276 highlights
34 FCR-1005 Recommended Action Verify that the devices were intended to be taken offline. If not, verify that the devices are functioning properly. Verify that all small form-factor pluggables (SFPs) are seated correctly. Check for faulty cables, deteriorated SFPs, or dirty connections. Replace the cables and SFPs if necessary. Severity INFO FCR-1005 Message , [FCR-1005], ,, INFO, , FC router LSAN zone device removed at port . Probable Cause Indicates that a device is removed from the logical storage area network (LSAN) zone in the edge fabric. Recommended No action is required. Action Severity INFO FCR-1006 Message , [FCR-1006], ,, INFO, , FC router LSAN zone device added at port . Probable Cause Indicates that a device is added to a logical storage area network (LSAN) zone in the edge fabric. Recommended No action is required. Action Severity INFO FCR-1007 Message , [FCR-1007], ,, INFO, , FC router LSAN zone deleted at port . Probable Cause Indicates that a logical storage area network (LSAN) zone attached to the specified port was deleted from the edge fabric. Recommended No action is required. Action Severity INFO FCR-1008 Message , [FCR-1008], ,, INFO, , FC router LSAN zone created at port . 206 Fabric OS Message Reference 53-1001338-01