HP StorageWorks 8/24 Brocade Fabric OS Message Reference v6.3.0 (53-1001338-01 - Page 533
PLAT System Messages
View all HP StorageWorks 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 533 highlights
Chapter PLAT System Messages 77 PLAT-1000 Message , [PLAT-1000], , FFDC, CRITICAL, , Probable Cause Indicates nonrecoverable PCI errors have been detected. Recommended Action The system will be faulted and might automatically reboot. If the system does not reboot, then try issuing the reboot command from a command-line prompt. Run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity CRITICAL PLAT-1001 Message , [PLAT-1001], ,, INFO, , CP resetting other CP (double reset may occur). Probable Cause Indicates the other CP is being reset. This message is typically generated by a CP that is in the process of becoming the active CP. Note that in certain circumstances a CP may experience a double reset and reboot twice in a row. A CP can recover automatically even if it has rebooted twice. Recommended No action is required. Action Severity INFO PLAT-1002 Message , [PLAT-1002], ,, CRITICAL, , CP : CP Fence CP Error . Probable Cause Indicates that the CP cannot access the I2C subsystem either because of an error condtion or being fenced or isolated from the I2C bus. Recommended Reboot the CP if it does not reboot itself. Reseat the CP if rebooting does not solve the problem. If Action the problem still persists, then replace the CP. Fabric OS Message Reference 463 53-1001338-01