26 FABR-1041 FABR-1041 Message , [FABR-1041], , ERROR, , Port is disabled due to trunk protocol error. Probable Cause Indicates that a link reset was received before the completion of the trunking protocol on the port. Recommended Action Enable the port by running the portEnable command. The port may recover by re-initialization of the link. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers followed by the supportSave command and contact your switch service provider. Severity ERROR FABR-1043 Message , [FABR-1043], , ERROR, , Detected Fabric ID conflict with remote (not neighbor) switch (domain ), FID . No local E-ports disabled. Probable Cause Indicates that the remote switch has a Fabric ID conflict with the local switch. But no ports are disabled because the remote switch is not adjacent to the local switch. Recommended Make sure that all the switches in the fabric have the same Fabric ID or upgrade the switch Action firmware to a VF-capable firmware. Severity ERROR FABR-1044 Message , [FABR-1044], , ERROR, , Detected Fabric ID conflict with neighbor switch (domain ), FID . E-ports () connected to the switch are disabled. Probable Cause Indicates that the neighbor switch has a Fabric ID conflict with the local switch. All E_ports directly connected to the conflicting switch are disabled. Recommended Make sure that all the switches in the fabric have the same fabric ID or upgrade the switch Action firmware to a VF-capable firmware. Severity ERROR FABR-1045 Message Probable Cause , [FABR-1045], , ERROR, , Detected Base Switch conflict with remote (not neighbor) switch (domain ), BS . No local E-ports disabled. Indicates that the remote switch has a Base Switch attribute conflict with the local switch. But no ports are disabled because the remote switch is not adjacent to the local switch. 180 Fabric OS Message Reference 53-1001338-01