HP StorageWorks 8/8 Brocade Fabric OS Message Reference guide v6.2.0 (53-10011 - Page 113
BL-1017, Recommended, Action, systemVerification, diagPost, Severity, Message, Probable Cause
View all HP StorageWorks 8/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
BL-1017 5 Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, reboot or power cycle the blade. Run the systemVerification command to verify that the blade does not have hardware problems. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands. If the message persists, replace the blade. Severity CRITICAL BL-1017 Message , [BL-1017], ,, INFO, , Slot Initializing... Probable Cause Indicates that the slot has started initializing the ports. Recommended No action is required. Action Severity INFO BL-1018 Message , [BL-1018], ,, INFO, , Slot Initialization completed. Probable Cause Indicates that the slot has completed initializing the ports. Recommended No action is required. Action Severity INFO BL-1019 Message , [BL-1019], ,, INFO, , Slot , retry , internal port retry initialization, . Probable Cause Indicates that the slot had internal ports not online and that the system is retrying to bring the ports that failed back online. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 55 53-1001157-01