Page 159 highlights
Chapter CVLMSystem Messages 16 CVLM-1001 Message , [CVLM-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function failed to allocate memory. Recommended Action • Check memory usage on the switch using the memShow command. • Reboot or power cycle the switch. Severity ERROR CVLM-1002 Message , [CVLM-1002], ,, ERROR, , Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the CVLMD failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR CVLM-1003 Message , [CVLM-1003], ,, INFO, , Crypto device configuration has been committed by switch (). Probable Cause Indicates --commit operation status. Recommended No action is required. Action Severity INFO CVLM-1004 Message , [CVLM-1004], ,, WARNING, , Crypto device configuration between local switch () and peer () is out of sync. New encryption session is not allowed. Fabric OS Message Reference 101 53-1001157-01