Table 3 Notification strings Notification string HPDSM_NEW_DEVICE Notification_ event_ number 1 HPDSM_ADDITIONAL_PATH 2 HPDSM_MAX_PATH_REACHED 3 HPDSM_LAST_PATH_FAILURE 4 HPDSM_PATH_FAILOVER 5 HPDSM_MAX_LUNS_REACHED 6 HPDSM_ALL_NOTIFICATIONS 7 Notifies the user when DSM: Detects a new device. Detects a redundant path to an existing device. Determines that a device configuration contains the maximum number of supported paths. Detects that the last path to the device is removed. Detects an existing path to a device has failed and an alternate path is being used. Determines that the configuration contains the maximum number of supported LUNs. Detects any event related to MPIO framework and DSM occurs. These notifications are sent by the HP MPIO MSA DSM and MPIO framework to the CLI. The CLI displays the event in the command window as shown in the following example:. Example: HPDSM NOTIFY EVENT=7 TIME=5 Received HPDSM_PATH_FAILOVER from HPMSADSM Received HPDSM_PATH_FAILOVER from HPMSADSM Received HPDSM_PATH_FAILOVER from HPMSADSM Received HPDSM_PATH_FAILOVER from HPMSADSM Received HPDSM_PATH_FAILOVER from HPMSADSM Received HPDSM_PATH_FAILOVER from HPMSADSM Received HPDSM_DEVICE_FAILURE from HPMSADSM Received HPDSM_DEVICE_FAILURE from HPMSADSM Received HPDSM_DEVICE_FAILURE from HPMSADSM Received HPDSM_DEVICE_FAILURE from HPMSADSM Received HPDSM_DEVICE_FAILURE from HPMSADSM Received HPDSM_DEVICE_FAILURE from HPMSADSM hpdsm help Syntax: hpdsm help The hpdsm help command displays help information for the CLI. HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.00.00 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

Table 3 Noti
cation strings
Noti
cation string
Noti
cation_ event_
number
Noti
es the user when DSM:
HPDSM_NEW_DEVICE
1
Detects a new device.
HPDSM_ADDITIONAL_PATH
2
Detects a redundant path to an existing
device.
HPDSM_MAX_PATH_REACHED
3
Determines that a device con
guration
contains the maximum number of
supported paths.
HPDSM_LAST_PATH_FAILURE
4
Detects that the last path to the device
is removed.
HPDSM_PATH_FAILOVER
5
Detects an existing path to a device
has failed and an alternate path is
being used.
HPDSM_MAX_LUNS_REACHED
6
Determines that the con
guration
contains the maximum number of
supported LUNs.
HPDSM_ALL_NOTIFICATIONS
7
Detects any event related to MPIO
framework and DSM occurs.
These noti
cations are sent by the HP MPIO MSA DSM and MPIO framework to the CLI. The CLI displays
the event in the command window as shown in the following example:.
Example:
HPDSM NOTIFY EVENT=7 TIME=5
Received HPDSM_PATH_FAILOVER from HPMSADSM
Received HPDSM_PATH_FAILOVER from HPMSADSM
Received HPDSM_PATH_FAILOVER from HPMSADSM
Received HPDSM_PATH_FAILOVER from HPMSADSM
Received HPDSM_PATH_FAILOVER from HPMSADSM
Received HPDSM_PATH_FAILOVER from HPMSADSM
Received HPDSM_DEVICE_FAILURE from HPMSADSM
Received HPDSM_DEVICE_FAILURE from HPMSADSM
Received HPDSM_DEVICE_FAILURE from HPMSADSM
Received HPDSM_DEVICE_FAILURE from HPMSADSM
Received HPDSM_DEVICE_FAILURE from HPMSADSM
Received HPDSM_DEVICE_FAILURE from HPMSADSM
hpdsm help
Syntax:
hpdsm help
The
hpdsm help
command displays help information for the CLI.
HP MPIO Full Featured DSM for MSA1000/1500 (Active-Active) Disk Arrays 3.00.00