Table 5-18, POST error messages, continued
UPC - 882780706422
View all HP Xw4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 135 highlights
Table 5-18 POST error messages (continued) Screen message Probable cause Recommended action 150-SafePost Active A PCI expansion card is not responding. 1. Restart the workstation. 2. Disable SafePost. 3. If the expansion card does not respond, replace the card. 162-System Options Not Set Configuration incorrect. RTC battery might need to be replaced. 1. Run Computer Setup (F10 Setup). 2. Set the date and time under Control Panel or in F10 Setup depending on the operating system. 3. If the problem persists, replace the RTC battery. 163-Time and Date Not Set Invalid time or date in configuration memory. RTC battery might need to be replaced. 1. Set the date and time under Control Panel or in F10 Setup depending on the operating system. 2. If the problem persists, replace the RTC battery. CMOS jumper might not be properly installed. 164-Memory Size Error Memory configuration is incorrect. 1. Run Computer Setup (F10 Setup) or Windows utilities. 2. Be sure memory modules (if any) are installed properly. 3. If third-party memory has been added, test using HP memory only. 4. Verify proper memory module type. 183-Invalid Processor Jumper Setting System board jumper improperly set. Reset system board jumpers to match processor and bus speeds (select models). 201-Memory Error RAM failure. 1. Run Computer Setup (F10 Setup) or Windows utilities. 2. Be sure that memory and continuity modules are installed correctly. 3. Verify proper memory module type. 4. Remove and replace memory modules one at a time to isolate faulty module. 5. Replace the faulty memory modules. 6. If error persists after replacing memory modules, replace the system board. 202-Memory Type Mismatch Memory modules do not match each Replace memory modules with matched sets. other. 207-ECC Corrected Single Single-bit ECC error. Bit Errors 1. Verify proper memory module type. 2. Insert the DIMM in another memory socket. 3. Replace memory module if problem persists. 212-Failed Processor Processor has failed to initialize. 1. Reseat the processor in its socket. 2. If the processor does not respond, replace it. ENWW POST and error messages 125