HP Xw4400 HP xw4400 Workstation - Service and Technical Reference Guide - Page 67
Predisassembly procedures, System board components
UPC - 882780706422
View all HP Xw4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 67 highlights
Predisassembly procedures Perform the following steps before servicing the workstation: 1. Close any open software applications. 2. Remove any diskettes or CDs from the workstation. 3. Shut down the operating system. 4. Power off the workstation and any peripheral devices that are connected to it. 5. Remove or disengage any security devices that prohibit opening the workstation. 6. Disconnect the power cord from the electrical outlet and then from the workstation. 7. Disconnect all peripheral device cables from the workstation. System board components The following image shows the system board connectors and sockets on the HP xw4400 Workstation. Figure 4-2 System board identification Table 4-3 System board components No. Component No. Component 1 Second serial port adapter 12 Battery 2 Rear chassis fan 13 Serial ATA 3 Auxiliary power 14 Clear CMOS button 4 Processor 15 Front chassis fan 5 Solenoid hood lock 16 Front control panel 6 Processor fan 17 Front chassis fan No. Component 23 Auxiliary audio 24 PCI 32/33 25 PCI Express x1 26 PCI Express x16 (4) 27 PCI 32/33 28 PCI Express x16 ENWW Predisassembly procedures 57