J Specifications Dimensions Width (side to side) Height (top to bottom) Depth (front to back) Approximate Weight Temperature Range (fanless design)* Operating** (max. rate of change is 10°C per hour or 18°F per hour) Nonoperating (max. rate of change is 20°C per hour or 36°F per hour) *Specifications are at sea level with altitude derating of 1°C/300 m (1.8°F/1000 ft) to a maximum of 3 Km (10,000 ft), with no direct, sustained sunlight. Upper limit may be limited by the type and number of options installed. Relative Humidity (non-condensing) Operating (max. wet bulb temperature is 28°C or 84.2°F) Nonoperating (max. wet bulb temperature is 38.7°C or 101.6°F) Maximum Altitude (unpressurized) Operating (max. allowed rate of change is 457 m per minute or 1500 ft per minute) Nonoperating (max. allowed rate of change is 457 m per minute or 1500 ft per minute) Power Supply Operating Input Voltage Range Rated Line Frequency Power Output (maximum) Rated Output Current (maximum) Output Voltage 180 mm 35 mm 140 mm 740 g 10° to 35°C -30° to 60°C 7.1 in 1.4 in 5.5 in 1.63 lbs 50° to 95°F -22° to 140°F ** The operating temperature range when the thin client is attached to a flat panel using the HP Quick Release is 10° to 35°C (50° to 95°F). 10-90% 5-95% 3048 m 9144 m 10,000 ft 30,000 ft 100-240 VAC 50-60 Hz 45 W 2.31 A +19.5 V DC 40 Appendix J Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

J
Specifications
Dimensions
Width (side to side)
Height (top to bottom)
Depth (front to back)
180 mm
35 mm
140 mm
7.1 in
1.4 in
5.5 in
Approximate Weight
740 g
1.63 lbs
Temperature Range
(fanless design)*
Operating**
(max. rate of change is 10°C per hour or 18°F per hour)
Nonoperating
(max. rate of change is 20°C per hour or 36°F per hour)
10° to 35°C
-30° to 60°C
50° to 95°F
-22° to 140°F
*Specifications
are at sea level with altitude derating of
1°C/300 m (1.8°F/1000 ft) to a maximum of 3 Km (10,000 ft),
with no direct, sustained sunlight. Upper limit may be limited
by the type and number of options installed.
** The operating temperature range when the thin client is
attached to a
flat
panel using the HP Quick Release is 10°
to 35°C (50° to 95°F).
Relative Humidity
(non-condensing)
Operating
(max. wet bulb temperature is 28°C or 84.2°F)
Nonoperating
(max. wet bulb temperature is 38.7°C or 101.6°F)
10–90%
5–95%
Maximum Altitude
(unpressurized)
Operating
(max. allowed rate of change is 457 m per minute or 1500 ft
per minute)
Nonoperating
(max. allowed rate of change is 457 m per minute or 1500 ft
per minute)
3048 m
9144 m
10,000 ft
30,000 ft
Power Supply
Operating Input Voltage Range
Rated Line Frequency
100–240 VAC
50–60 Hz
Power Output
(maximum)
45 W
Rated Output Current
(maximum)
2.31 A
Output Voltage
+19.5 V DC
40
Appendix J
Specifications