Hitachi NR90GC Service Manual - Page 53
is used for the Seal Lock Hex. Socket Hd. Bolt M5 x 10
UPC - 717709008533
View all Hitachi NR90GC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
Mount the Pushing Lever Spring [63] and insert the Cylinder Ass'y [42] into the Housing [71]. At this time, fit the convex portion of the Pushing Lever Connector [68] in the end of the Pushing Lever Spring [63] being careful not to remove the Pushing Lever Spring [63] (Fig. 45). Cylinder Ass'y [42] Pushing Lever Spring [63] Convex portion Fig. 45 Pushing Lever Connector [68] Secure the Cylinder Plate [57] to the Cylinder Ass'y [42] with the Seal Lock Hex. Socket Hd. Bolt M5 x 10 [58] and join the Cylinder Ass'y [42] with the Housing [71]. Make the Cylinder Plate [57] contact with the convex portion of the cylinder. Do not tighten the Seal Lock Hex. Socket Hd. Bolt M5 x 10 [58] with the Cylinder Plate [57] overlapped on the convex portion (Fig. 46). At this time, insert the Blade Guide [53] between the Cylinder Ass'y [42] and the Cylinder Plate [57]. * Because it is difficult to mount the Blade Guide [53] later because the Cylinder Plate [57] pushes the Blade Guide [53]. * Do not use any bolt other than the Seal Lock Hex. Socket Hd. Bolt M5 x 10 [58] because a special adhesive is used for the Seal Lock Hex. Socket Hd. Bolt M5 x 10 [58]. Finally, secure the Switch Plate [34] to the Chamber [24] with the Machine Screw M4 x 6 [33]. * After mounting the Cylinder Ass'y [42] to the Housing [71], mount the Switch Plate [34] to the Chamber [24]. Note that the Cylinder Ass'y [42] cannot be mounted to the Housing [71] if the Switch Plate [34] is mounted to the Chamber [24] first. --- 50 ---