Honeywell HM509H8908 Owners Guide - Page 19
Important for Remote Installation - service
UPC - 085267313476
View all Honeywell HM509H8908 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
TrueSTEAM Humidification System Wiring 13 Slide the cover back into place and secure captive screw. Turn on the water supply and plug in the humidifier. POWER HUMIDIFYING CLEAN TANK SEE LABEL BELOW ! CALL SERVICE PRESS RESET PRESS EMPTY 14 The Press Reset light will blink when power is applied. Press/release the RESET button to ready the TrueSTEAM. If not pushed, TrueSTEAM will automatically move to ready after five minutes. RESET EMPTY M24762 15 M24763 Turn the humidity control to the "Test" position. If the "Test" position is unavailable, turn the control to a high setpoint (60% +). Be sure to turn this back down (or off) when testing is complete. "Off" will turn TrueSTEAM off. 16 Confirm that the furnace blower turns on to circulate air. This will take about 10-15 minutes upon call for humidity. Important for Remote Installation: After TrueSTEAM has produced steam for 10-15 minutes, check the integrity of the remote hose to ensure no sags have occurred. Add or adjust clamps if necessary to ensure 2 in. per foot continuous slope. 17 69-2036EFS-07