TrueSTEAM Humidification System Cleaning and Seasonal or Vacation Maintenance 7. Replace inline filter once per year. Turn water supply off before replacing. Press down filter collar ring and pull out 1/4 in. water line from each side. Insert 1/4 in. lines into new filter. Apply modest pressure to ensure a tight fit. M27410 M27411 Once clean, reattach tank by securing the latch. Engage the water valve to the cam shaft, and "Lock" the shut-off valve. The "Press Reset" light will blink at start-up. Push the RESET button to ready the humidifier. 25 69-2036EFS-07
TrueSTEAM Humidification System
2³
69-2036EFS—07
CLEANING AND SEASONAL OR VACATION MAINTENANCE
7. Replace inline filter once per year. Turn water supply off before replacing.
Press down filter collar ring and pull
out 1/4 in. water line from each side.
Insert 1/4 in. lines into new filter. Apply
modest pressure to ensure a tight fit.
M27410
M27411
Once clean, reattach tank by securing the latch. Engage the water valve to the cam shaft, and
“Lock” the shut-off valve. The “Press Reset” light will blink at start-up. Push the RESET button
to ready the humidifier.