Honeywell VISTA 15P Operation Guide - Page 17

Connecting Relay Modules, Powerline Carrier Devices and Output Triggers - security panel

Page 17 highlights

Mounting and Wiring the Control Connecting Relay Modules, Powerline Carrier Devices and Output Triggers 4204/4229 Relay Modules 1. Mount either remotely or in the control panel. 2. Connect each module to the control's keypad terminals and set the device addresses as previously described in the Connecting Keypads and Other Addressable Device section. Use the connector harness supplied with the module. Use standard 4-conductor twisted cable for long wiring runs. VISTA-20P: Up to 16 relays (if no powerline carrier devices are used) VISTA-15P: Up to 8 relays (if no powerline carrier devices are used) 3. Connect the desired field wiring to the unit's relay contact terminals. UL For UL installation requirements, refer to the Installation Instructions for the 4204. Powerline Carrier Devices UL Powerline Carrier devices and the 1361X10 Transformer are not UL Listed for fire or burglary functions and are intended for home automation. 1 2 3 4 5 6 7 8 9 10 11 12 4204 RELAY C DIP SWITCH 4 NC TYPICAL FOR SETTING DEVICE ADDRESS (SHOWN "OFF") NO AND ENABLING/DISABLING TAMPER RELAY C COVER TAMPER (REED) SWITCH 3 NC NO 4-PIN TOUCHPAD PLUG EITHER OR BOTH CAN BE USED TB1 RELAY C 2 NC NO RELAY C 1 NC 13 14 15 16 NO YEL DATA IN TB2 FROM CONTROL BLK (-) GROUND GRN DATA OUT RED TO CONTROL (+) 12V 4204_conn-1-V0 Figure 13. 4204 Connections to Control • Supervision: 4204 and 4229 modules are supervised against removal. The module's device address is displayed as follows if a module is disconnected from the control's terminals, or if the module cover is removed and the tamper jumper is installed: Alpha: CHECK xx Wire Expansion FAULT xx Wire Expansion ALARM xx Wire Expansion Fixed-Glass: lxx (or 91 if field *199 set for 2-digit display) where "xx is the module's address. • If communication/tamper failure occurs on a device with zones wired to it, all zones on the device will be displayed in their respective partitions. 1. Install the powerline carrier devices according to the instructions included with each. VISTA-20P: Up to 16 devices (if no relays are used) VISTA-15P: Up to 8 devices (if no relays are used) 2. Use Programming Mode to enter the device house ID in data field*27, and enter the unit code using *79 Output Device menu Mode. 3. See connections diagram in the AC Wiring section for connecting the 1361X10 transformer to the triggers. • You must use a 1361X10 Transformer instead of the 1321 Transformer. • The 1361X10 Transformer provides AC power to the control panel, and also supplies signals from the control panel through the premises AC wiring to the Powerline Carrier devices (which are plugged into AC outlets). You can then make devices that are plugged into Powerline Carrier devices perform various functions in response to commands you enter at the security system keypads. Canada: Use the PSC04 Powerline Interface as shown below. 8-PIN TRIGGER CONNECTOR 1 345678 KEY (BLACK) (PURPLE) (BLUE) OUTPUT 18 (GREEN) (YELLOW) +12 AUX. (ORANGE) (RED) OUTPUT 17 SYNC COM DATA GND (-) SA4120XM-1 CABLE SYNC COM DATA BLK GRN RED YEL X-10 PSC04 POWERLINE INTERFACE 1 2 3 4 MODULAR PHONE CORD (not supplied) 1 - BLACK 2 - RED 3 - GREEN 4 - YELLOW Figure 14. PSC04 Powerline Interface Connections 2-11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Connecting Relay Modules, Powerline Carrier Devices and Output Triggers
4204/4229 Relay Modules
U
L
For UL installation
requirements, refer to the
Installation Instructions for
the 4204.
1. Mount either remotely or in the control panel.
2. Connect each module to the control’s keypad terminals and set the device addresses
as previously described in the
Connecting Keypads and Other Addressable
Device
section. Use the connector harness supplied with the module. Use standard
4-conductor twisted cable for long wiring runs.
VISTA-20P: Up to 16 relays (if no powerline carrier devices are used)
VISTA-15P: Up to 8 relays (if no powerline carrier devices are used)
3. Connect the desired field wiring to the unit's relay contact terminals.
TB2
12
11
10
9
8
7
6
5
4
3
2
1
(
) GROUND
(+) 12V
YEL
BLK
GRN
RED
13
14
15
16
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER
(REED)
SWITCH
TB1
4204
4-PIN TOUCHPAD PLUG
3
2
RELAY
1
4
TYPICAL
(SHOWN "OFF")
C
NC
NO
C
NC
NO
C
NC
4204_conn-1-V0
NC
NO
C
NC
NO
EITHER OR BOTH
CAN BE USED
DATA IN
FROM CONTROL
DATA OUT
TO CONTROL
RELAY
RELAY
RELAY
Figure 13. 4204 Connections to Control
Supervision: 4204 and 4229 modules are supervised against removal. The module’s
device address is displayed as follows if a module is disconnected from the control’s
terminals, or if the module cover is removed and the tamper jumper is installed:
Alpha: CHECK xx
Wire Expansion
FAULT xx
Wire Expansion
ALARM xx Wire Expansion
Fixed-Glass:
lxx (or 91 if field *199 set for 2-digit display)
where “xx is the module’s address.
If communication/tamper failure occurs on a device with zones wired to it, all zones on
the device will be displayed in their respective partitions.
Powerline Carrier
Devices
U
L
Powerline Carrier
devices and the 1361X10
Transformer are not UL
Listed for fire or burglary
functions and are intended
for home automation.
1. Install the powerline carrier devices according to the instructions included with each.
VISTA-20P: Up to 16 devices (if no relays are used)
VISTA-15P: Up to 8 devices (if no relays are used)
2. Use Programming Mode to enter the device house ID in data field*27, and enter the
unit code using *79 Output Device menu Mode.
3. See connections diagram in the AC Wiring section for connecting the 1361X10
transformer to the triggers.
You must use a 1361X10 Transformer instead of the 1321 Transformer.
The 1361X10 Transformer provides AC power to the control panel, and also supplies
signals from the control panel through the premises AC wiring to the Powerline
Carrier devices (which are plugged into AC outlets). You can then make devices that
are plugged into Powerline Carrier devices perform various functions in response to
commands you enter at the security system keypads.
Canada: Use the PSC04 Powerline Interface as shown below.
1 2 3 4
SA4120XM-1 CABLE
X-10 PSC04
POWERLINE INTERFACE
YEL
RED
GRN
BLK
MODULAR PHONE CORD (not supplied)
1 - BLACK
2 - RED
3 - GREEN
4 - YELLOW
SYNC
DATA
COM
1
3
4
5
6
7
8
KEY
+12 AUX.
DATA
COM
SYNC
GND (-)
OUTPUT 17
(RED)
OUTPUT 18
(GREEN)
(ORANGE)
(YELLOW)
(BLUE)
(PURPLE)
(BLACK)
8-PIN TRIGGER CONNECTOR
Figure 14. PSC04 Powerline Interface Connections
Mounting and Wiring the Control
2-11