Honeywell VISTA 15P Operation Guide - Page 8
Auxiliary Device Current Draw Worksheet - kits
UPC - 781410414846
View all Honeywell VISTA 15P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Installation and Setup Guide CABINET A B RECEIVER CIRCUIT BOARD + + CONTROL CIRCUIT BOARD BOARD SUPPORTING SLOTS MOUNTING CLIP MOUNTING CLIP CABINET CIRCUIT BOARD DETAIL A SIDE VIEW OF BOARD SUPPORTING SLOTS INSTALLATION WITH RECEIVER CIRCUIT BOARD ANTENNA (2) SCREW (2) GROUNDING LUG (2) WHITE MOUNTING CLIP BLACK MOUNTING CLIP RED MOUNTING CLIP NOTE A COMBINATION OF THESE MOUNTING CLIPS HAS BEEN INCLUDED IN YOUR INSTALLATION KIT. USE THE APPROPRIATE CLIPS FOR MOUNTING. IF NO RF RECEIVER IS USED, MOUNT THE PC BOARD USING EITHER THE WHITE OR BLACK CLIPS, WHICHEVER ARE INCLUDED IN THE CONTROL PANEL'S HARDWARE KIT. ANTENNA MOUNT (2 PLACES) DETAIL B ANTENNA AND GROUNDING LUG INSTALLATION pc_mount-001-V1 Figure 3. Mounting the PC Board and RF Receiver Auxiliary Device Current Draw Worksheet DEVICE CURRENT 6150 Fixed-Word Keypad 40mA/70mA** 6160 Alpha Keypad 40mA/150mA** 6150V Fixed-Word Display Voice Keypad 60mA/160mA** 6160V Alpha Display Voice Keypad 60mA/190mA** 8132/8142 Series AUI (Symphony) 150mA/400mA** 6270 Touch Screen Keypad 180mA/280mA** 5881/5882 RF Receiver 60mA 5883 Transceiver 80mA 4219 Zone Expander 30mA 4204 Relay Unit 15/180mA‡ 4229 Zone Expander/Relay Unit 30/100mA‡ 4286 Phone Module 300mA No. UNITS TOTAL CURRENT * (Current available from Aux. terminals = 600 mA max.)† TOTAL = *If using hardwire devices such as PIRs, refer to the specifications for that particular unit's current draw. ** Values are for standby/alarm; alarm for keypads means armed with backlighting on and sounder on †In UL installations, maximum current draw from the Auxiliary Output and the Alarm Output combined must not exceed 600 mA (500 mA max from Aux. Output). ‡Values are for relays OFF/relays ON. CALIFORNIA STATE FIRE MARSHALL (CSFM) AND UL RESIDENTIAL FIRE 24-HOUR BATTERY BACKUP REQUIREMENTS The California State Fire Marshal and UL have regulations which require that all residential fire alarm control panels must be provided with a backup battery which has sufficient capacity to operate the panel and its attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4 minutes in the intended fire alarm signaling condition. This control panel can meet these requirements without using a supplementary power supply, provided that the panel's auxiliary power and bell output currents are limited as indicated below. OUTPUT LIMITATIONS AND CORRESPONDING REQUIRED BATTERIES OUTPUT CURRENT LIMITATIONS BATTERY INFORMATION Output Current Total Maximum Auxiliary Current Battery Capacity Recommended Battery To Use (Amp/Hrs) (Yuasa Model No.) 600mA maximum total of 45mA 4AH NP4-12 (or ADEMCO 467) auxiliary power plus bell 160mA 7AH NP7-12 output currents 200mA 8AH NP4-12 (two) ‡ 425mA 14AH NP7-12 (two) ‡ 500mA 17.2AH NPG18-12 ‡ NOTE: Use two batteries, connected in parallel. Obtain an Ademco Battery Harness Kit SA5140-1. (Both batteries will fit inside the cabinet.) 2-2