Honeywell VISTA 15P Operation Guide - Page 39
Summary of Connections - 15psia
UPC - 781410414846
View all Honeywell VISTA 15P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
24-HR BATTERY STANDBY REQUIRED FOR FIRE INSTALLATIONS. USE 12V, 17.2AH BATTERY FOR 600mA AUX POWER. SEE INSTRUCTIONS. BATTERY CAPACITY FOR EMERGENCY BURGLARY STANDBY USE AT LEAST 4 HRS CHARGING VOLTAGE 13.8VDC. MAXIMUM CHARGING CURRENT 650mA. BATTERY 12V, 4AH + SEALED LEAD-ACID TYPE. BATTERY NORMALLY NEED NOT BE REPLACED FOR AT LEAST 3 YRS. TO DETERMINE TOTAL STANDBY LOAD ON BATTERY, ADD 100mA TO TOTAL OF AUX. POWER OUTPUT AND REMOTE KEYPAD CURRENTS. BATTERY FUSE (IF INSTALLED.) 3A FOR REPLACEMENT, USE SAME VALUE (e.g. ADEMCO No. 90-12) FUSE NOTE MAY HAVE PTC IN PLACE OF FUSE. 8-PIN CONNECTOR USED FOR 1361X10 TRANSFORMER CONNECTIONS AND FOR ON-BOARD TRIGGERS SEE INSTRUCTIONS. 1 2 3 4 5 6 78 FOR COMPLETE INFORMATION, SEE INSTRUCTIONS K5305-1V5 OR LATER. (USE SA4120XM-1 CABLE) SYNC BLACK RED + FLYING LEADS FOR BATTERY CONNECTION COM DATA TO TRANS. TO TERM 4 BLK RED JUMPER CUT FOR BELL SUPERVISION. ALSO, CONNECT 2000 OHM RESISTOR DIRECTLY ACROSS SOUNDER. TO TERM 5 TO TERM 6 TO TERM 7 RED GRN YEL OUTPUT 17 (TRIG. 1) +12 AUX GND OUTPUT 18 (TRIG. 2) OPTIONAL FOR UP TO 40 ADDITIONAL ZONES ( FROM EITHER OR BOTH GROUPS) BLK RED GRN YEL BLK RED GRN YEL ADEMCO No. 4219 WIRED EXPANSION MODULE (8 ADD'L EOLR WIRED ZONES) -AND/ORADEMCO No. 4229 WIRED EXPANSION/RELAY MODULE (8 ADD'L EOLR WIRED ZONES PLUS 2 OUTPUT RELAYS) -AND/ORADEMCO No. 4204 RELAY MODULE (4 OUTPUT RELAYS) AND/OR ADEMCO 5881* Type RF RECEIVER WIRELESS ZONES 5881L: UP TO 8 5881M: UP TO 16 5881H: UP TO 56 *5882 IN CANADA SET UNIT'S DIP SWITCH FOR DEVICE ADDRESSES 7 - 15 SEE INSTRUCTIONS. SET RECEIVER'S DIP SWITCH FOR DEVICE ADDRESS OF "0". SEE INSTRUCTIONS. 4-WIRE SMOKE DETECTOR CONNECTIONS +5 AUX PWR OUTPUT TERMINALS PROGRAM RELAY AS ZONE TYPE 54 (FIRE ZONE RESET) RELAY BLK _4 N.C. OR CONTACT OPENS MOMENTARILY UPON FIRE ALARM RESET TO OUTPUT 17 PROGRAM OUTPUT 17 FOR "OUT NORM LOW" = YES IN 79 MENU MODE AND AS ZONE TYPE 54 IN 80 MENU MODE MAX. CURRENT = 100 mA + _ 4-WIRE SMOKE OR COMBUSTION DETECTOR _ + N.O. VIOLET 2000 OHMS EOLR RED EOL POWER SUPERVISION RELAY MODULE A77-716B. USE N.O. CONTACT, WHICH CLOSES WHEN POWER IS APPLIED. TO ZONE TERM. ( +) TO ZONE TERM. (_) HEAT DETECTOR } } } Figure 17. Summary of Connections 7-5 USE UL LISTED LIMITED ENERGY CABLE FOR ALL CONNECTIONS CLASS 2 PLUG-IN TRANSFORMER 16.5VAC, 25VA (e.g. ADEMCO No. 1321). (USE No. 1321CN IN CANADA) USE 1361X10 TRANSFORMER INTERFACE IN PLACE OF 1321 OR 1321CN WHEN POWER LINE CARRIER DEVICES ARE BEING USED. (SEE INSTRUCTIONS FOR CONNECTIONS) THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S STANDARD 72, CHAPTER 11 (NATIONAL FIRE PROTECTION ASSOCIATION, BATTERY-MARCH PARK, QUINCY,MA 02169). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, OPERATION,TESTING, MAINTENANCE, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT. CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITTED ONLY WITH THE PERMISSION OF THE LOCAL AUTHORITY HAVING JURISDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT BE CONNECTED TO A POLICE EMERGENCY NUMBER. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 LO ZONE 6 HI HI ZONE 7 LO HI ZONE 5 LO HI LO LO ZONE 2 HI HI ZONE 3 LO ZONE 1 LO HI BLACK: KEYPAD GROUND (- ) RETURN L + L CAN BE USED FOR 2-WIRE SMOKE DETECTORS BLK RED: KEYPAD PWR ( + ) GREEN: DATA IN FROM KEYPAD YELLOW: KEYPAD DATA OUT TO 110VAC UNSWITCHED OUTLET (24HR) AUX. POWER OUTPUT 10.5-13.8VDC 600mA MAX. (500mA MAX. FOR UL INSTALLATIONS) + ALARM OUTPUT 10.5-13.8VDC, 2A MAX. (600mA MAX. FOR UL USAGE, INCLUDING AUX POWER) STEADY FOR BURGLARY/PANIC, TEMPORAL PULSE SOUNDING FOR FIRE. CAN USE ADEMCO No. 702 SIREN, OR 12V BELL). SEE INSTRUCTIONS. ALL OUTPUTS ARE POWER LIMITED. NOTE: KEYPAD (S) CURRENT (IN BOTH PARTITIONS) AND ALL OTHER DEVICES DRAWING POWER FROM TERMS 4 & 5 MUST BE INCLUDED IN AUX CURRENT DRAIN CALCULATIONS. WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. IN ADDITION, THIS SYSTEM MUST BE CHECKED BY A QUALIFIED TECHNICIAN AT LEAST ONCE EVERY THREE (3) YEARS. REMOTE KEYPADS AND OTHER ADDRESSABLE DEVICES (e.g. 5800TM, 4286, LRR, 4219, 4229, 4204, 5881) REMOTE KEYPADS CAN USE 6150 OR 6160 KEYPADS. LOCAL PROGRAMMING MUST BE DONE WITH A 6160, BUT NEED NOT REMAIN IN THE SYSTEM (SET TO ADDRESS 16). 2000 OHMS EOLR 12 2000 OHMS EOLR 13 14 2k TAMPER CONTACTS 2k 2k 2k 2k 2k ZONE 3 ZONE 4 TYPICAL WIRING FOR DOUBLE BALANCED ZONE (VISTA-20P ONLY) ZONE 4 2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR • MAXIMUM LOOP RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR) • RESPONSE, ZONES 1-8: 10, 350, OR 700 MSEC (PROGRAMMABLE) • MAXIMUM NUMBER OF 2-WIRE SMOKE DETECTORS ON ZONE 1 IS 16; DETECTORS MUST HAVE COMPATIBILITY IDENTIFIER AS "A". 10 11 ZONE 2 3k ZONE 10 ZONE PAIRS 2 / 10 3 / 11 4 / 12 5 / 13 6 / 14 7 / 15 8 / 16 POWER SHUTDOWN NOTE: SYSTEM SHUTS DOWN SENSOR DETECTION PROCESSING IF CONTROL'S VOLTAGE DROPS BELOW 9.6V. ALL DEVICES AND ACCESSORIES USED IN A CANADIAN INSTALLATION MUST BE LISTED FOR USE IN CANADA 6.2k TYPICAL WIRING FOR ZONE DOUBLING (VISTA-20P ONLY) ADEMCO VISTA-20P / VISTA-20PSIA SERIES / VISTA-15P / VISTA-15PSIA SERIES SUMMARY OF CONNECTIONS LO ZONE 8 HI VISTA-20P ONLY 21 22 23 24 25 TIP RING TIP RING (BROWN) (GRAY) (GREEN) (RED) HANDSET INCOMING PHONE LINE TELEPHONE WIRING (VIA RJ31X* JACK AND DIRECT CONNECT CORD) *CA38A IN CANADA DOC LOAD NO.: 3 EARTH GROUND SEE INSTRUCTIONS FOR PROPER GROUNDING FOR CONNECTION OF OPTIONAL 4286 VIP MODULE TO PHONE TERMINALS, SEE INSTRUCTIONS. WARNING:TO PREVENT RISK OF SHOCK, DISCONNECT TELEPHONE LINE AT TELCO JACK BEFORE SERVICING THIS UNIT. COMPLIES WITH FCC RULES, PART 68. FCC REGISTRATION NO. 5GBUSA-44003-AL-E RINGER EQUIVALENCE: 0.1B. V20P_V15P-SOC-V9