IBM 865811Y User Guide

IBM 865811Y - Netfinity 5100 - 8658 Manual

IBM 865811Y manual content summary:

  • IBM 865811Y | User Guide - Page 1
    Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY S10K-2615-00
  • IBM 865811Y | User Guide - Page 2
  • IBM 865811Y | User Guide - Page 3
    Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY S10K-2615-00
  • IBM 865811Y | User Guide - Page 4
    Note: Before using this information and the product it supports, be sure to read the general information under " . This publication was developed for products and services offered in the United States of America. IBM may not offer the products, services, or features discussed in this document in
  • IBM 865811Y | User Guide - Page 5
    the Netfinity 5100 server. Important: This manual is intended for trained servicers who are familiar with IBM PC Server products. Important safety information Be sure to read all caution and danger statements in this book before performing any of the instructions. Leia todas as instruções de cuidado
  • IBM 865811Y | User Guide - Page 6
    .us.pc.ibm.com/files.html IBM Online Addresses The HMM manuals online address is: http://www.us.pc.ibm.com/cdt/hmm.html The IBM PC Company Support Page is: http://www.us.pc.ibm.com/support/index.html The IBM PC Company Home Page is: http://www.pc.ibm.com iv : Netfinity 5100 Type 8658 Models 11Y, 21Y
  • IBM 865811Y | User Guide - Page 7
    Contents About this manual iii Important safety information iii Online Support iv IBM Online Addresses iv General checkout 1 General information 3 Features and specifications 3 What your IBM Netfinity 5100 offers 5 Reliability, availability, and serviceability features . . 6 Server controls
  • IBM 865811Y | User Guide - Page 8
    IBM support 96 DB2 database support support Supported and certified databases . . . . 105 Starting Netfinity Manager 106 Netfinity Manager Service Manager . . . . . 107 Netfinity Manager service Service service Problems 145 Parts listing (Type 8658 147 Keyboards 149 Power cords 150 Related service
  • IBM 865811Y | User Guide - Page 9
    Safety inspection guide 154 Handling electrostatic discharge-sensitive devices 155 Grounding requirements 155 Safety notices (multi-lingual translations) . . . 155 Send us your comments 185 Problem determination tips 185 Notices 186 Trademarks 186 Contents vii
  • IBM 865811Y | User Guide - Page 10
    viii : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 11
    you cannot determine whether a problem is caused by the hardware diagnostic programs, a single problem might cause several error computer hangs and no error is displayed, go to "Undetermined Problems" on page 145. 5. Power supply problems page 152. 7. For intermittent problems, check the error log;
  • IBM 865811Y | User Guide - Page 12
    -on all external devices. v Power-on the computer. v Record any POST error messages displayed on the the following responses: a. One beep. b. Readable instructions or the Main Menu. 3. DID YOU RECEIVE problem, see "Undetermined Problems" on page 145. 2 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y
  • IBM 865811Y | User Guide - Page 13
    IBM Netfinity 5100 server comes with a three-year limited warranty and IBM Netfinity/PC Server 90-Day Start Up Support. ibm.com/pc/register To find the meanings of various computer-related terms, you can access the IBM Netfinity 5100 at the following World Wide Web address: http://www.networking.ibm
  • IBM 865811Y | User Guide - Page 14
    hour: v Minimum configuration: 683 BTU (200 watts) v Maximum configuration: 2048 BTU (600 watts) Electrical input: v Sine-wave input (50-60 Hz) required 4 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 15
    0.08 kVA - Maximum: 0.42 kVA What your IBM Netfinity 5100 offers The unique design of your server capabilities All models of the server support up to six hot-swap hard on your server is less than 250 watts and a problem occurs with one of the power supplies, the other as the service processor. Refer
  • IBM 865811Y | User Guide - Page 16
    . As always, your IBM server meets stringent worldwide serviceability features Three of the most important features in server design are reliability, availability, and serviceability v Remote system problem-determination support v Power and 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY,
  • IBM 865811Y | User Guide - Page 17
    v Parity checking on the SCSI and PCI buses v Error checking and correcting (ECC) memory v Redundant hot-swap power supply option v Redundant hot-swap cooling v Redundant Ethernet capabilities (with optional adapter) v Vital Product Data (VPD) on processor complex, system board, power backplane,
  • IBM 865811Y | User Guide - Page 18
    of the hot-swap drives has a Hard Disk Activity light. When this green light is flashing, the controller is accessing the drive. 8 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 19
    Rear view (tower shown) 1 AC power LED 2 DC power LED AC Power Light: This light provides status information about the power supply. During normal operation, both the AC and DC Power lights are on. For any other combination of lights, see "Power supply LEDs" on page 14. DC Power Light: This
  • IBM 865811Y | User Guide - Page 20
    the Power control button starts an orderly shutdown of the operating system, if this feature is supported by your operating system, and places the server in standby mode. Note: After turning off to stop blinking. 10 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 21
    Operator Information panel The operator information panel on the front of the server contains status lights. OK 100 LINK TX MB OK RX 1 Information light 2 System error light 3 Ethernet transmit/receive activity light 4 Ethernet link status light 5 Ethernet speed light 6 Power-on light
  • IBM 865811Y | User Guide - Page 22
    Ethernet Transmit/Receive Activity Light: This green LED lights when there is transmit or receive activity to or from the server. 12 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 23
    troubleshooting information to help you resolve some common problems that might occur with your server. Diagnostic tools overview The following tools are available to help you identify and resolve hardware-related problems The System Event/Error Log contains all error © Copyright IBM Corp. 2000 13
  • IBM 865811Y | User Guide - Page 24
    , select Event/Error Logs from the main menu. Small computer system interface messages The table in "SCSI error codes" messages only when running the SCSISelect Utility. Identifying problems using status LEDs If the System Error light in 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 25
    the major components of your server. Diagnostic error messages indicate that a problem exists; they are not intended to be used to identify a displays more than one error message. Always follow the suggested action instructions for the first error message that appears. The following sections
  • IBM 865811Y | User Guide - Page 26
    Specific String This is additional information that you can use to analyze the problem. Starting the diagnostic programs You can press F1 while running the diagnostic ; then, follow the instructions on the screen. 16 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY,
  • IBM 865811Y | User Guide - Page 27
    OK but the problem persists during normal server operations, a software error might be the cause. If you suspect a software problem, refer to the 4. Select View Test Log from the list that appears; then, follow the instructions on the screen. The system maintains the test-log data while the server
  • IBM 865811Y | User Guide - Page 28
    Wide Web. Go to http://www.pc.ibm.com/support/, select IBM Server Support, and make the selections for your server. normally. Troubleshooting the Ethernet controller This section provides troubleshooting information for problems that might 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 29
    v Determine if the hub supports auto-negotiation. If not, try configuring the integrated Ethernet controller manually to match the speed and duplex mode of the hub. v Check the Ethernet controller lights on the operator information panel. These lights indicate whether a problem exists with the
  • IBM 865811Y | User Guide - Page 30
    Table 1. Ethernet troubleshooting chart (continued) Ethernet controller problem Suggested Action The Ethernet Transmit/Receive Activity light does not light. Check " on page 16 to run the diagnostic programs. 20 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 31
    adapter could not be found. Action: Verify that you installed an IBM Netfinity 10/100 Fault Tolerant Adapter and make sure that the adapter is Multiple Link Interface Driver (MLID) cannot be registered with the Link Support Layer (LSL). Explanation: An error occurred while the driver was trying to
  • IBM 865811Y | User Guide - Page 32
    the PCI bus. Action: Verify that the Ethernet controller is enabled. If the problem persists, go to "Starting the diagnostic programs" on page 16 to run the drivers, and suggested actions to resolve each problem. 22 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY,
  • IBM 865811Y | User Guide - Page 33
    Table 3. NDIS 2.01 (OS/2) driver messages for the Ethernet controller PCNTND-1 Unable to open the Protocol Manager. Explanation: The NDIS stack is not configured correctly. Action: Check and correct your configuration. PCNTND-6 Out of memory while allocating buffers. Explanation: The driver could
  • IBM 865811Y | User Guide - Page 34
    to the Secondary Adapter. PermaNet Server: Explanation: The system detected a problem with the primary Ethernet connection and has transferred all network traffic to and suggested actions to resolve each problem. 24 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 35
    Solaris driver has been reset due to a device fault. Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic programs. IRQ found for PCnet hardware does not match space
  • IBM 865811Y | User Guide - Page 36
    power problems is as follows: 1. Power off the system and disconnect the AC cord(s). 2. Check for loose cables in the power subsystem. Also check for short circuits, for instance if there is a loose screw causing a short circuit on a circuit board. 26 : Netfinity 5100 Type 8658 Models 11Y, 21Y
  • IBM 865811Y | User Guide - Page 37
    successfully, replace adapters and devices one at a time until the problem is isolated. If system does not power up from minimal configuration, replace FRUs , you must adhere to the following instructions. CAUTION: When replacing the battery, use only IBM Part Number 10L6432 or an equivalent type
  • IBM 865811Y | User Guide - Page 38
    the rear of the server v The top cover is removed for no longer than 30 minutes while the server is operating 28 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 39
    server is operating v A removed hot-swap drive is replaced within two minutes of removal v Cables for optional adapters are routed according to the instructions provided with the adapters (ensure that cables are not restricting air flow) v The fans are operating correctly and the air flow is good
  • IBM 865811Y | User Guide - Page 40
    30 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 41
    ServerGuide CDs include software setup and installation tools specifically designed for IBM Netfinity servers. You can use these CDs during the initial to access the full Configuration/Setup menu. 3. Follow the instructions that appear on the screen. Choices available from the Configuration/Setup
  • IBM 865811Y | User Guide - Page 42
    following: IBM Netfinity Setup - © IBM Corporation 1998 Configuration/Setup Utility • System Summary • System Information • Devices and I/O Ports • Date and Time /Setup Utility main menu. v Date and Time 32 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 43
    change the system time sent to the Advanced System Management Processor (service processor) when the server is started. This choice appears only to be added or subtracted from the system time that is sent to the service processor (Configuration/Setup Utility) each time the server is started. Use the
  • IBM 865811Y | User Guide - Page 44
    options are configured incorrectly. Follow the instructions on the screen carefully. - Processor changes here unless directed to do so by an IBM authorized service representative. - Cache Control Select this choice to must manually 34 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY
  • IBM 865811Y | User Guide - Page 45
    enable the memory bank after the problem is corrected. Select Memory Settings from the Advanced Setup menu, use the arrow keys to highlight the bank that you want to enable; then, use the arrow keys to select Enable. v System Service Processor Settings Select this choice to view the interrupt-
  • IBM 865811Y | User Guide - Page 46
    : If an administrator password is set and then forgotten, it cannot be overridden or removed. You must replace the system board. 36 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 47
    default SCSI IDs v Locate and correct configuration conflicts v Perform a low-level format on a SCSI hard disk The following sections provide the instructions needed to start the SCSISelect Utility and descriptions of the menu choices available. Note: If your server has a RAID adapter installed, use
  • IBM 865811Y | User Guide - Page 48
    controller to its default values, press F6; then, follow the instructions that appear on the screen. You can view or change These options include enabling support for large hard disk drives and support for drives with UltraSCSI speeds Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 49
    Format Disk; then, follow the instructions on the screen. Note: Hard disks normally contain more tracks than their stated capacity (to allow for defective tracks). A message appears on the screen if the defect limit is reached. If this happens, have the system serviced. Configuring the server 39
  • IBM 865811Y | User Guide - Page 50
    40 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 51
    server. Some option-removal instructions are provided, in case is running, provided that your system is configured to support this function. For complete information about installing or removing 5 Fan 6 Adapter-retention bracket 7 Adapter-support bracket 8 Fan (blower) System board layout
  • IBM 865811Y | User Guide - Page 52
    (J44) 10 Battery 11 PCI slot 4 64-bit (J39) 12 PCI slot 3 64-bit (J34) 13 PCI slot 2 32-bit (J32) 42 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 53
    System board internal cable connectors The following illustration identifies system-board connectors for internal cables. 1 Fan 3 (J35) 2 Main Power (J4) 3 Power (J51) 4 DASD (SCSI) system management (J5) 5 Power system management (J12) 6 Fan 1 (J59) 7 Operator information panel (J50)
  • IBM 865811Y | User Guide - Page 54
    switches 1-4). See Table 8 on page 45 for specific settings. 4 Microprocessor speed setting (requires switches 1-4). SeeTable 8 on page 45 for specific settings. 44 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 55
    to change the speed settings. System board LED locations The following illustration identifies system-board LEDs. You may need to refer to this figure when troubleshooting a problem. 1 Secondary microprocessor failure (CR7) Installing options 45
  • IBM 865811Y | User Guide - Page 56
    components. This means that you can install or remove the component while the system is running, provided that your system is configured to support this function. For complete details about installing or removing a hot-swap component, see the information provided in this chapter. 46 : Netfinity 5100
  • IBM 865811Y | User Guide - Page 57
    -blade screwdriver available. v For a list of supported options for your server, refer to http://www.ibm.com/pc/us/compat on the World Wide Web minutes of removal. v Cables for optional adapters are routed according to the instructions provided with the adapters. v A failed fan is replaced within 48
  • IBM 865811Y | User Guide - Page 58
    internal option, do not open the static-protective package containing the option until you are instructed to do so. When you handle options and other server components, take these precautions models), and the bezel. 48 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 59
    Removing the left-side cover (tower model) Note: To remove or install a hot-swap hard disk drive or hot-swap power supply, it is not necessary to remove the cover. 1 Cover release lever 2 Left-side cover To remove the left-side cover of the tower model: 1. Review the information in "Before you
  • IBM 865811Y | User Guide - Page 60
    To remove the server door: 1. Unlock and open the server door. 2. Locate the flange on the top edge of the door. 50 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 61
    3. Press down on the flange while pressing out on the door; then, lift the server door up and off the hinge. Set the door aside in a safe place. Removing the bezel (rack or tower) 1 Bezel-release lever 2 Bezel To remove the bezel: 1. Move the blue bezel-release lever, following the curve of the
  • IBM 865811Y | User Guide - Page 62
    with the adapter and follow those instructions in addition to the instructions given in this chapter. If , you can install a variety of PCI adapters that currently do not support sharing of PCI interrupts. v PCI slots 1 and 2 are on PCI 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 63
    Installing an adapter 1 Adapter support bracket 2 Support bracket bezel 3 Adapter 4 Expansion slot cover 5 3. Determine which expansion slot you will use for the adapter. Note: Check the instructions that come with the adapter for any requirements or restrictions. 4. Remove the expansion-
  • IBM 865811Y | User Guide - Page 64
    damage to the system board or the adapter. d. Close the retaining flap on the adapter support bracket, if you opened it. e. Align the bottom tabs of the adapter retention bracket with additional power supplies. 54 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 65
    Tower model 1 Non-hot-swap bay D 2 SCSI ID 0 3 Hard disk activity light 4 Hard disk status light 5 SCSI ID 2 6 SCSI ID 3 7 SCSI ID 4 8 SCSI ID 8 9 SCSI ID 9 10 Hot swap bays 11 Non-hot-swap bay C 12 Non-hot-swap bay B 13 Non-hot-swap bay A Installing options 55
  • IBM 865811Y | User Guide - Page 66
    attachment (SCA) connector. Hot-swap-drive trays come with the hot-swap drives. v Your server supports six slim (1-inch) or three half-high (1.6-inch), 3.5-inch hot-swap hard disk drives in the A, B, C, and D only. 56 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 67
    -ROM drive in bay C. v The Netfinity 5100 server supports only one diskette drive. v The diskette drive uses To order the converter, contact your IBM reseller or IBM marketing representative. Note: The server's want to install the drive. 3. Check the instructions that come with the drive to see if
  • IBM 865811Y | User Guide - Page 68
    (that is, perpendicular to the drive). b. Align the rails on the drive/tray assembly with the guide rails in the drive bay. c. Gently push the drive/tray assembly into the bay until the drive up all important data. 58 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 69
    2. To avoid damage to a hard disk drive, DO NOT remove the drive from the hot-swap bay until it has had time to spin down (approximately 30 seconds). Handle the drive carefully. 3. Before you hot-swap a drive, make sure it is defective. If you partially or completely remove a good drive instead of a
  • IBM 865811Y | User Guide - Page 70
    (that is, perpendicular to the drive). b. Align the rails on the drive/tray assembly with the guide rails in the drive bay. c. Gently push the drive/tray assembly into the bay until the drive non-hot-swap bays: 60 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 71
    (DLT) backup drive, the slide rails and screws are included in the optional power supply backplane kit. 7. Align the rails on the drive with the guide rails in the drive bay. 8. Push the drive into the bay until it clicks into place. 9. If the drive is an IDE device: v Make sure
  • IBM 865811Y | User Guide - Page 72
    illustration for memory connector locations.) 2. Your Netfinity 5100 server supports 128 MB, 256 MB, 512 MB, and 1 GB DIMMs. Your server supports a minimum of 128 MB and a maximum of 4 GB with the connector. 62 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 73
    for your server is available through the World Wide Web. 2. Obtain an SMP-capable operating system (optional). For a list of supported operating systems, see http://www.ibm.com/pc/us/compat/ on the World Wide Web. 3. The microprocessor that is installed in microprocessor connector U3 is CPU 1 or
  • IBM 865811Y | User Guide - Page 74
    you remove the microprocessor later, remember to install the terminator card in the appropriate microprocessor connector and to remove the VRM. 64 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 75
    6. If you replaced the microprocessor with a different speed microprocessor, change switches 1-4 on the switch block to the appropriate settings, as shown in the following table. Table 10. Microprocessor speed settings Microprocessor speed 667/133 733/133 800/133 Switch 1 On On Off Switch 2 On
  • IBM 865811Y | User Guide - Page 76
    this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Adding a power supply If supply is operating properly. 66 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 77
    Note: You do not need to turn off the power to the server to install hot-swap power supplies. 1 Power supply backplane option 2 Cable-restraint bracket 3 Power supply handle (in open position) 4 Power supply 5 Filler panel To install a hot-swap power supply: 1. Remove the filler panel
  • IBM 865811Y | User Guide - Page 78
    power supply. Attention: Be careful when you remove the power supply; the power supply might be too hot to handle comfortably. 68 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 79
    CAUTION: The following label indicates a hot surface nearby. b. Remove the defective power supply by placing the handle of the power supply in the open position (perpendicular to the power supply) and pulling the power supply from the bay. 3. Install a replacement power supply: a. Place the handle
  • IBM 865811Y | User Guide - Page 80
    the cover against the server and slide the cover toward the front of the server until the cover clicks into place. 70 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 81
    Installing the bezel and front door 1 Bezel 2 Server door 3 Flange To install the bezel: 1. Place the tabs at the bottom edge of the bezel in the slots at the bottom front of the server. 2. Press the top of the bezel toward the server until the bezel clicks into place. To install the server
  • IBM 865811Y | User Guide - Page 82
    : 1. Read "Before you begin" on page 46' and the documentation that comes with your options. 2. Turn off the server and all attached devices. 3. Follow the instructions that come with the option to prepare it for installation and to connect it to the server. 72 : Netfinity 5100 Type
  • IBM 865811Y | User Guide - Page 83
    I/O connector locations The following illustration shows the input/output connectors (ports) and the expansion slots on the rear of the server. For pin assignments and other details about these connectors, see "Input/Output ports." 1 Advanced System Management Interconnect knockout 2 Parallel 3
  • IBM 865811Y | User Guide - Page 84
    from and written to a device. In bidirectional mode, the server supports the ECP and EPP modes. To view or change the parallel- 8 I/O Data 6 EPP Signal -WRITE Data 0 Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 74 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 85
    Table 11. Parallel-port connector pin-number assignments (continued) 9 I/O Data 7 Data 7 10 I -ACK -ACK 11 I BUSY -WAIT 12 I PE (paper end) PE (paper end) 13 I SLCT (select) SLCT (select) 14 O -AUTO FD (feed) -AUTO FD 15 I -ERROR -ERROR 16 O -INIT -INIT 17 O -SLCT
  • IBM 865811Y | User Guide - Page 86
    connectors on the rear of your server. Table 13. USB-port connector pin-number assignments Pin Signal 1 VCC 2 -Data 3 +Data 4 Ground 76 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 87
    Ground 4 N/A +5 V dc 5 I/O Keyboard clock 6 N/A Reserved Auxiliary-device (pointing device) port The system board has one auxiliary-device port that supports a mouse or other pointing device. The following table shows the pin-number assignments for the auxiliary-device connector on the
  • IBM 865811Y | User Guide - Page 88
    -channel Ultra3 small computer system interface (SCSI) controller. This controller supports two independent Ultra 160/m SCSI channels, both internal. Each of these channels supports up to 15 SCSI the RAID adapter. 78 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 89
    correct cables for use with external devices, contact your IBM reseller or IBM marketing representative. For information about the maximum length of device. Refer to the information that is provided with the device for instructions to set its SCSI ID. SCSI connector pin-number assignments The
  • IBM 865811Y | User Guide - Page 90
    Ethernet (100BASE-TX), half duplex (HDX), or full duplex (FDX). The controller supports half-duplex (HDX) and full-duplex (FDX) modes at both speeds. The Ethernet provided on the ServerGuide CDs. Failover for redundant Ethernet The IBM Netfinity 10/100 Fault Tolerant Adapter is an optional redundant
  • IBM 865811Y | User Guide - Page 91
    can be automatic or manually controlled, depending on the a faulty adapter causes a network problem, or if you want to IBM Operating System/2 (OS/2): 1. Add the redundant NIC adapter according to the instructions that are provided with the adapter. Note: The OS/2 operating system does not support
  • IBM 865811Y | User Guide - Page 92
    : 1. Download the IBM PCI Hot Plug Services EXE file from the Netfinity Support web page and extract the files onto a diskette. 2. Log on to Windows NT Server as a user in the Administrator group. 3. Insert the diskette into the diskette drive. 82 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y
  • IBM 865811Y | User Guide - Page 93
    of the Adapter Properties panel. If you do not have the IBM Netfinity Hot Plug PCI for Windows NT Server 4.0 package installed on your server Hot Swap Support checkbox is checked, a DMI alert will also be generated. IntraNetWare: 1. Add the redundant NIC adapter according to the instructions that are
  • IBM 865811Y | User Guide - Page 94
    the D-shell system-management connector on the rear of your server to communicate with the integrated Netfinity Advanced System Management Processor. 84 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 95
    The RS-485 function uses the RJ-45 system-management connectors. This function enables you to connect the Advanced System Management Processors of several rack-mounted servers so that they can communicate with each other in half-duplex mode. Cabling the server When you cable the server, be sure to
  • IBM 865811Y | User Guide - Page 96
    Additionally, for rack models, be sure to route the cables through the cable-management arm on the rack. Cable straps 86 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 97
    network. Furthermore, additional Netfinity Manager and Client Services for Netfinity Manager licenses are available for purchase from your IBM representative. Note: This section provides installation instructions for all operating systems supported by Netfinity Manager. However, not all operating
  • IBM 865811Y | User Guide - Page 98
    and one or more of the following communications protocols: - IBM TCP/IP for OS/2 version 1.2 or later (required for the other supported SNA stacks. v A 9600 baud or greater modem (optional). The hard disk requirement for Client Services for 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY,
  • IBM 865811Y | User Guide - Page 99
    Microsoft SNA Server can communicate with other Netfinity Manager systems using any of the other supported SNA stacks. v A 9600 baud or greater modem (optional). The hard disk requirement for Client Services for Netfinity Manager is 6.5 MB-9 MB of hard disk space. All other system requirements are
  • IBM 865811Y | User Guide - Page 100
    Netfinity Manager User's Guide for additional installation instructions. d. Click Install Product to start the installation process. v Windows 95, 98, or NT a. Click the Start button. b. Click Run... from the Start button menu. c. Type x:\SCW95 90 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y
  • IBM 865811Y | User Guide - Page 101
    IBM Netfinity Manager from the Available Applications selection list. Note: To install Client Services for Netfinity Manager, select Client Services and then refer to the Client Services for Netfinity Manager User's Guide for additional installation instructions. e. Click Install Product to start
  • IBM 865811Y | User Guide - Page 102
    The available installation options are: v Advanced System Management Support Click Advanced System Management Support to install the Advanced System Management service on this system. Use this service to monitor and manage IBM Advanced System Management processors and adapters. Important: If you
  • IBM 865811Y | User Guide - Page 103
    Control v Service Configuration Manager v Service Processor Manager v Service Manager v be installed regardless of whether the system has a DMI Service Layer, ECC Memory, a System Partition, a RAID adapter base program that enables local use of the service only if the required hardware or system
  • IBM 865811Y | User Guide - Page 104
    must be unique to the system. If this name is not unique, it can prevent remote Netfinity Manager users from using the Serial Connection Control service to access the system. c. Enable the Network Driver. 94 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 105
    by a remote user. The alert includes the name of the service that was run and information about the user that started the service. v Show Network Support If the Show Network Support option is enabled, the Netfinity Manager Support Program (or Network Interface) will be visible as a minimized process
  • IBM 865811Y | User Guide - Page 106
    ODBC as well. Once support for one or more of these databases has been installed along with Netfinity Manager, data can be exported from these Netfinity Manager services: v Alert Manager v Software Inventory v System Information Tool 96 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y
  • IBM 865811Y | User Guide - Page 107
    support" on page 102. DB2 database support Support for DB2 database export is automatically configured during installation of the Netfinity Manager. However, the database system itself must be configured. Instructions DB2 Installation Guide for general requirements and supported protocols. Installing
  • IBM 865811Y | User Guide - Page 108
    the DB2 Netfinity database, connect to the database now. 2. Type the following command: DB2 GRANT privilegecode ON TABLE tablename TO userid 98 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 109
    name of the table as specified during database installation. A listing of the Netfinity database table names can be found in the Netfinity User's Guide (Appendix H: Netfinity Relational Database Tables). Note: The Netfinity Database Administration Tool can also be used to GRANT or REVOKE privileges
  • IBM 865811Y | User Guide - Page 110
    Manager to discontinue export data through ODBC for use on DB2, refer to "ODBC database support" on page 102. Cataloging the database in the managing system: If the manager is using execution. 5. Press Enter. 100 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 111
    For information on what versions of Lotus Notes and the Lotus Notes client are supported, see Table 19 on page 105. See the Notes Administrator's Guide for general system requirements and supported communications protocols. Installing the database To enable Netfinity Manager to export system data to
  • IBM 865811Y | User Guide - Page 112
    data gathered by specific Netfinity Manager services. Click the name of the service that gathers the data to Expand in the View pull-down menu. ODBC database support Netfinity Manager supports exporting data via ODBC for use on SQL or DB2 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY,
  • IBM 865811Y | User Guide - Page 113
    Visigenic driver provided with Microsoft SQL Server) or - IBM DB2 For detailed information about supported ODBC platforms, see Table 19 on page 105. Support Program to export data using the ODBC database. a. Open Services from the Control Panel. b. Click Netfinity Support Program from the Services
  • IBM 865811Y | User Guide - Page 114
    export data: 1. Open the Netfinity Manager Database Administration service. The Netfinity Manager Database Administration service is found in the Netfinity Manager folder or Netfinity also available: v Delete 104 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 115
    use with this release of Netfinity Manager. Table 19. Supported Netfinity Databases.. Reference by operating system and database client Connect OS/2 Warp 4.0 IBM DB2 Version Yes Yes Yes Yes Yes 2.1.2 IBM DB2 Universal Yes Yes Yes Yes Yes Database 5.0 ODBC - IBM DB2 Version 2.1.2 Yes,
  • IBM 865811Y | User Guide - Page 116
    Supported Netfinity Databases. (continued). Reference by operating system and database client version. Product Win 95 Win NT 3.51 Win NT 4.0 OS/2 Warp Connect OS/2 Warp 4.0 ODBC - IBM Netfinity Manager Service Manager object. 106 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY,
  • IBM 865811Y | User Guide - Page 117
    " in Netfinity Manager Quick Beginnings. 2. Start the Netfinity Service Manager. To start the Netfinity Service Manager, double-click the Netfinity Service Manager object. Netfinity Manager Service Manager All Netfinity Manager services that are supported by the operating system can be started from
  • IBM 865811Y | User Guide - Page 118
    -specific chapters of the Netfinity Manager User's Guide. Advanced System Management The Advanced System Management service provides extensive functionality available for your IBM PC Server Advanced System Management Adapter, 108 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY
  • IBM 865811Y | User Guide - Page 119
    any action taken by the Alert Manager. Individual or multiple alerts can be selected from the log and printed for later reference, or deleted once problems are corrected. This service is available for stand-alone use and network use. Alert on LAN configuration Use the Alert on LAN configuration
  • IBM 865811Y | User Guide - Page 120
    any Netfinity Manager service on any Netfinity Manager system in the network. The Netfinity Manager system on the network is organized into easy-to-manage logical groups that can be updated automatically using the auto-discovery feature. 110 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y
  • IBM 865811Y | User Guide - Page 121
    Services service can prevent unauthorized access to some or all of the Netfinity Manager services Control service enables Connection Control service, you supports at least 9600 baud for the Serial Connection Control service to function. Service Configuration Manager Service that support ROM problems
  • IBM 865811Y | User Guide - Page 122
    most detail is provided when this service is used with IBM computers. This service is available for both stand-alone and network use. System Monitor The System Monitor up correctly or to allow your system to fully 112 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 123
    command line functions. Client Services for Netfinity Installation and setup information for Client Services for Manager Quick Beginnings Netfinity Manager. Client Services for Netfinity Detailed information on how to use Client Services for Manager User's Guide Netfinity Manager. Netfinity
  • IBM 865811Y | User Guide - Page 124
    Services for Netfinity Manager for SCO UnixWare. User's Guide LAN CID, included with IBM Network Transport Services/2), Netfinity Manager can /SERVICES directory into the source directory. 3. Copy the files from the appropriate Netfinity Manager directory. 114 : Netfinity 5100 Type 8658 Models 11Y,
  • IBM 865811Y | User Guide - Page 125
    program command-line parameters. The Netfinity Manager installation program supports the following command-line parameters: /R: drive+path+filename access to all services. User access can be restricted by creating a customized installation that will prevent some services from being installed.
  • IBM 865811Y | User Guide - Page 126
    IBM SysMgt Install Script, Version 2 (Do not remove this comment line) Netfinity Manager Installation [Manager 16900] Advanced System Management Support semicolon in front of any service that you want to remove from the installation. 116 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY
  • IBM 865811Y | User Guide - Page 127
    To add a line item in a specific section, add all the necessary item information in the format shown in the following example. Before: Screen Capture GUI NULL Manager CL 0 1 SAVEG.EXE CL 0 1 SAVEG.HLP After: Screen Capture GUI NULL Manager CL 0 1 SAVEG.EXE CL 0 1 SAVEG.HLP CL 0 1 CUSTOM.INI
  • IBM 865811Y | User Guide - Page 128
    118 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 129
    only) Field Replacement Units (FRUs) should be replaced by qualified service personnel only. Note: Before performing any removals, read "Safety information" on page 152 and "Before you begin the LED card 2 away from the front bezel to slide the card out of the slot. © Copyright IBM Corp. 2000 119
  • IBM 865811Y | User Guide - Page 130
    arrow on the tab 1 to release. 4. Gently pull the power reset card 3 out of slots 2 to remove from the front panel. 120 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 131
    bracket 1 to release the bracket arm. 4. Carefully peel away the adhesive strip 2 . 5. Remove the screws 3 . 6. Gently pull the rear cable bracket 1 to remove. FRU information (service only) 121
  • IBM 865811Y | User Guide - Page 132
    arrow on the tab 1 to release the backplane. 6. Carefully slide out the DASD backplane 2 to remove. Removing the power supply backplane 122 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 133
    the power supply backplane" on page 122.″ 7. Disconnect the system board cables. 8. Remove the screws (9) 1 . 9. Gently pull out the system board 2 to remove. FRU information (service only) 123
  • IBM 865811Y | User Guide - Page 134
    124 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 135
    supports Netfinity 5100 servers. The Symptom-to-FRU lists symptoms, errors, and the possible causes. The most likely cause is listed first. Use this Symptom-to-FRU index to help you decide which FRUs to have available when servicing the computer DIMM 2. System Board © Copyright IBM Corp. 2000 125
  • IBM 865811Y | User Guide - Page 136
    3-2-1 (Serial port failed) 1. System Board 3-2-2 (Parallel port failed) 1. System Board 3-2-4 (Failure comparing CMOS memory size against actual) 1. DIMM 2. System Board 3. Battery 126 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 137
    Beep/Symptom FRU/Action 3-3-1 (Memory size mis-match occurred; see "Memory Settings″ on page 34) 1. DIMM 2. System Board 3. Battery 3-3-2 (Critical SMBUS error occurred) 1. Disconnect the server power cord from outlet, wait 30 seconds and retry. 2. System Board 3. DIMMs 4. DASD Backplane 5.
  • IBM 865811Y | User Guide - Page 138
    ; clear the log. System Error Log for error condition, then clear System Error Log when the problem is found.) 2. PFA alert; check Netfinity log for failure; clear PFA alert; remove AC power 3. SCSI Backplane. 128 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 139
    Diagnostic Panel LED FRU/Action DASD2 LED on (The LED 1. Be sure the fans are operating correctly and the air flow is located next to the drive good. bay that the failing drive is installed in will be turned on. Check amber drive LED for failing hard drive.) 2. Failing drive. SCSI channel B
  • IBM 865811Y | User Guide - Page 140
    1. System Board Port test) 014-XXX-000 (Failed Parallel Port 1. System Board test) 015-XXX-001 (Failed USB test) 1. System Board 130 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 141
    basic and extended configuration status and refer to the ServeRAID Hardware Maintenance Manual for more information. 2. Cable 3. SCSI Backplane 4. Adapter 075 test) 1. VRM 2 2. Microprocessor 2 165-XXX-000 (Failed Service Processor test) 1. System Board. Before replacing the System Board, ensure
  • IBM 865811Y | User Guide - Page 142
    BIOS Fixed Disk test) Note: If RAID is configured, the fixed disk number refers to the RAID logical array. 1. Fixed Disk 3 132 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 143
    Tape Drive with SCSI ID NN (Refer to the Help and Service Information appendix of the tape drive's User Guide). 4. System Board or SCSI Controller. (Run SCSI Controller end of a paper clip into the manual tray-release opening. 2. Run CD-ROM Diagnostic 3. CD-ROM Drive Symptom-to-FRU index 133
  • IBM 865811Y | User Guide - Page 144
    adjusting and testing instructions. 1. Monitor 2. Run Video Diagnostics. If diagnostics pass, the problem may be a video driver. 3. Display Adapter / System Board Power supply LED errors Use the power supply LED information on the following page to troubleshoot power supply problems. The minimum
  • IBM 865811Y | User Guide - Page 145
    devices. Power-on the system. If the DC Good LED comes on, replace the adapters and devices one at a time until you isolate the problem. 3. Power Supply 4. Power Backplane 5. System Board N/A POST error codes In the following error codes, X can be any number or letter. Error Code/Symptom FRU
  • IBM 865811Y | User Guide - Page 146
    Configuration/Setup 2. DIMM 3. System Board 175 (Hardware error) 1. System Board 176 (Computer cover or cable cover 1. Run Configuration/Setup was removed without a key being used) the administrator password 136 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 147
    Error Code/Symptom FRU/Action 201 (Memory test error, see ″Memory Settings″ on page 34.) If the server does not have the latest level of BIOS installed, update the BIOS to the latest level and run the diagnostic program again. 1. DIMM 2. System Board 229 (Cache error) 1. Processor 2. Optional
  • IBM 865811Y | User Guide - Page 148
    Assembly 4. System Board 1600 (The Service Processor is not functioning) Do the following able to communicate to the Service 1. System Board Processor, but the Service Processor failed to respond at -on the system. 2. Flash update the Service Processor. 1762 (Fixed Disk Configuration error)
  • IBM 865811Y | User Guide - Page 149
    Error Code/Symptom 178X (Fixed Disk error) 1800 (No more hardware interrupt available for PCI adapter) 1962 (Drive does not contain a valid boot sector) 2400 (Video controller test failure) 2462 (Video memory configuration error) 5962 (IDE CD-ROM configuration error) 8603 (Pointing Device Error)
  • IBM 865811Y | User Guide - Page 150
    system to hard disk drive. I9990650 (AC power has been restored) 1. Check cable 2. Check for interruption of power supply 3. Power Cable 140 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 151
    One or more of 1. External SCSI devices must be powered-on the following might be causing the before you power-on the server. problem: 2. The cables for all external SCSI devices are v A failing SCSI device (adapter, connected correctly. drive, controller) 3. If you have attached an external
  • IBM 865811Y | User Guide - Page 152
    " on page 26. 1. See "Power checkout" on page 26. 1. See "Power checkout" on page 26. 1. See "Power checkout" on page 26. 142 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 153
    "Power checkout" on page 26. System shutdown Refer to the following tables when experiencing system shutdown related to voltage or temperature problems. Voltage related system shutdown Message Action System shutoff due to ″X″ current over max value 1. See "Power checkout" on page 26 (level
  • IBM 865811Y | User Guide - Page 154
    Test (BIST) Message Host BIST fail (level-informational; host's built-in self test failed) Action 1. Reseat CPU 2. Reseat VRM 3. Replace CPU 144 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 155
    on the computer and reconfigure each time). v Any external devices v Surge suppressor device (on the computer) v Modem, printer, mouse, or non-IBM devices minimum of 1 bank of 128 MB DIMMs) 4. Power-on the computer. If the problem remains, suspect the following FRUs in the order listed: v Power
  • IBM 865811Y | User Guide - Page 156
    system, and replacing that adapter does not correct the problem, suspect the System Board. 2. If you suspect a networking problem and all the system tests pass, suspect a network cabling problem external to the system. 146 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY
  • IBM 865811Y | User Guide - Page 157
    Card Assembly (All Models) 2 667/133 Processor Assembly (Models 1RY, 11Y) 2 733/133 Processor Assembly (Models 2RY, 21Y) 3 Voltage Regulator Module (All Models) 4 800/133 Processor Assembly (Models 3RY, 31Y) © Copyright IBM Corp. 2000 FRU No. 37L5949 00N3622 00N7174 36L8901 09N9097 147
  • IBM 865811Y | User Guide - Page 158
    Assembly (Models 11Y, 21Y, Door Bezel Assembly (Models 11Y, 21Y, 31Y, 41Y Set Assembly (Models 11Y, 21Y, 31Y, Card Support Assembly Tower (Models 11Y, 21Y, 31Y 11Y, 21Y, 31Y, 41Y, 51Y) 00N6393 Keyboard (US) (Models 11Y, 21Y, 31Y, 41Y, 51Y) 37L2551 Mouse (Models 11Y -in (4) (Models 11Y, 21Y, 31Y, 41Y
  • IBM 865811Y | User Guide - Page 159
    37L2564 37L2565 37L2566 02K0901 37L2567 37L2568 37L2569 37L2570 37L2571 37L2572 37L2573 37L2574 37L2575 37L2576 37L2577 37L2578 37L2579 37L2580 37L2581 37L2582 37L2583 37L2585 Parts listing (Type 8658) 149
  • IBM 865811Y | User Guide - Page 160
    Jamaica, Korea (South), Liberia, Mexico, Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Suriname, Taiwan, Trinidad (West Indies), Venezuela United States of (220) 36L8886 (220V/15A) 150 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 161
    Note: The service procedures are designed to help you isolate problems. They are written with the assumption that you have model-specific training on all computers, or that are familiar with the computers, functions, terminology, and service information provided in this manual. © Copyright IBM Corp
  • IBM 865811Y | User Guide - Page 162
    information that you need to be familiar with before servicing an IBM mobile computer. General safety Follow these rules to ensure general safety the server covers, unless instructed otherwise in the installation and configuration procedures. 152 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y
  • IBM 865811Y | User Guide - Page 163
    special safety precautions when you work with very high voltages; these instructions are in the safety sections of maintenance information. Use extreme such touching can cause personal injury and machine damage. v Do not service the following parts with the power on when they are removed from their
  • IBM 865811Y | User Guide - Page 164
    protect users and service personnel from injury. This guide addresses only non-IBM features or options not covered by this inspection guide. If broken, or sharp edges). 2. Power-off the computer. Disconnect the power cord. 3. Check the power 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 165
    such as those listed below, to provide protection that meets the specific service requirement. Note: The use of a grounding system is desirable but prong of the ac plug on ac-operated computers. Grounding requirements Electrical grounding of the computer is required for operator safety and correct
  • IBM 865811Y | User Guide - Page 166
    sure to read all caution and danger statements before performing any of the instructions. v Statement 1 DANGER Electrical current from power, telephone and communication all cables from devices. v Statement 2 156 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 167
    CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or adjustments or performance of procedures
  • IBM 865811Y | User Guide - Page 168
    . 2 1 v Statement 10 CAUTION: Do not place any object weighing more than 82 kg (180 lbs.) on top of rack-mounted devices. 158 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 169
    Desconectar: 1. DESLIGUE Tudo. 2. Primeiramente, remova os cabos de alimentação das tomadas. 3. Remova os cabos de sinal dos conectores. 4. Remova todos os cabos dos dispositivos. Related service information 159
  • IBM 865811Y | User Guide - Page 170
    889-8986, para obter informações sobre como enviar a bateria pelo correio para a IBM. Instrução 3 PRECAUCIÓN: Quando produtos a laser (unidades de CD-ROM, unidades de evite exposição direta ao raio. Instrução 4 160 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 171
    fonte de energia elétrica. 2 1 CUIDADO: Instrução 10 CUIDADO: Não coloque nenhum objeto com peso superior a 82 kg (180 lbs.) sobre dispositivos montados em rack. Related service information 161
  • IBM 865811Y | User Guide - Page 172
    162 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 173
    Related service information 163
  • IBM 865811Y | User Guide - Page 174
    164 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 175
    Related service information 165
  • IBM 865811Y | User Guide - Page 176
    166 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 177
    Related service information 167
  • IBM 865811Y | User Guide - Page 178
    168 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 179
    la relient aux réseaux, aux systèmes de télécommunication et aux modems (sauf instruction contraire mentionnée dans les procédures d'installation et de configuration). v Lorsque vous câbles d'interface des connecteurs. 4. Débranchez tous les câbles des unités. Related service information 169
  • IBM 865811Y | User Guide - Page 180
    au lithium usagée par une pile de référence identique exclusivement - voir la référence IBM - ou par une pile équivalente recommandée par le fabricant. Si votre système une exposition directe au rayon. Notice n 4 170 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 181
    plusieurs cordons d'alimentation. Pour isoler totalement l'unité du réseau électrique, débranchez tous les cordons d'alimentation des socles de prise de courant. 2 1 Notice n 10 ATTENTION: Related service information 171
  • IBM 865811Y | User Guide - Page 182
    Anschlußbuchsen 3. Signalkabel von Anschlußbuchsen lösen. 4. Alle Kabel von Einheiten lösen. anschließen. 4. Netzstecker an Steckdose anschließen. 5. Gerät einschalten. 172 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 183
    Hinweis 2 ACHTUNG: Eine verbrauchte Batterie nur durch eine Batterie mit der IBM Teilenummer 33F8354 oder durch eine vom Hersteller empfohlene Batterie ersetzen. Wenn Ihr , nicht direkt mit optischen Instrumenten betrachten und den Strahlungsbereich meiden. Hinweis 4 Related service information 173
  • IBM 865811Y | User Guide - Page 184
    aus den Netzsteckdosen herausgezogen wurden. 2 1 Hinweis 10 ACHTUNG: Keine Gegenstände, die mehr als 82 kg wiegen, auf Rack-Einheiten ablegen. 174 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 185
    le unità. 1. SPEGNERE tutti i dispositivi. 2. Rimuovere prima i cavi di alimentazione dalle prese elettriche. 3. Rimuovere i cavi di segnale dai connettori. 4. Rimuovere tutti i cavi dalle unità. Related service information 175
  • IBM 865811Y | User Guide - Page 186
    la batteria al litio, utilizzare solo una batteria IBM con numero parte 33F8354 o batterie dello stesso l'esecuzione di procedure non descritti nel presente manuale possono provocare l'esposizione a radiazioni pericolose. PERICOLO 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY,
  • IBM 865811Y | User Guide - Page 187
    dalla sorgente di alimentazione. 2 1 Avviso 10 ATTENZIONE: Non poggiare oggetti che pesano più di 82 kg sulla parte superiore delle unità montate in rack. Related service information 177
  • IBM 865811Y | User Guide - Page 188
    178 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 189
    Related service information 179
  • IBM 865811Y | User Guide - Page 190
    180 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 191
    la tabla siguiente cuando desee realizar una operaciín de instalaciín, de traslado o de apertura de las cubiertas para este producto o para los dispositivos conectados. Related service information 181
  • IBM 865811Y | User Guide - Page 192
    desee sustituir la batería de litio, utilice únicamente el número de pieza 33F8354 de IBM o cualquier tipo de batería equivalente que recomiende el fabricante. Si el sistema tiene un perjudicial a las radiaciones. 182 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 193
    ín. Para eliminar la corriente eléctrica del dispositivo, asegúrese de desconectar todos los cables de alimentaciín de la fuente de alimentaciín. 2 1 Declaración 10 Related service information 183
  • IBM 865811Y | User Guide - Page 194
    PRECAUCIÓN: No coloque ningún objeto que pese más de 82 kg (180 libras) encima de los dispositivos montados en bastidor. 184 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 195
    combinations that can be encountered, use the following information to assist you in problem determination. If possible, have this information available when requesting assistance from Service Support and Engineering functions. v Machine type and model v Processor or hard disk upgrades v Failure
  • IBM 865811Y | User Guide - Page 196
    HelpCenter IBM NetBAY3 Netfinity Manager SystemXtra HelpFax OS/2 Netfinity ThinkPad The following terms are trademarks of other companies: Notes Lotus Development Corporation MMX and Pentium are trademarks or registered trademarks of Intel Corporation. 186 : Netfinity 5100 Type 8658 Models 11Y
  • IBM 865811Y | User Guide - Page 197
    UNIX is a trademark or registered trademark of The Open Group in the United States and other countries. Windows NT is a trademark or registered trademark of Microsoft Corporation. Related service information 187
  • IBM 865811Y | User Guide - Page 198
    188 : Netfinity 5100 Type 8658 Models 11Y, 21Y, 31Y, 41Y, 51Y, 1RY, 2RY, 3RY, 4RY, 5RY
  • IBM 865811Y | User Guide - Page 199
  • IBM 865811Y | User Guide - Page 200
    Part Number: 10K2615 Printed in USA S10K-2615-00 (1P) P/N: 10K2615
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

Netfinity
5100
Type
8658
Models
11Y,
21Y,
31Y,
41Y,
51Y,
1RY,
2RY,
3RY,
4RY,
5RY
S10K-2615-00
±²³