IBM 865811Y User Guide - Page 35

pnt0-2, search, specified, device, found, Explanation, Action, pnt0-6, pnt0-7, pnt0-11, Device, pnt0

Page 35 highlights

Table 5. UNIX LLI driver messages for the Ethernet controller pnt0-2 PCI search specified, PCI device not found! pnt0-6 Explanation: The driver cannot locate the Ethernet controller on the PCI bus. Action: v Run the NETCONFIG program to search for another Ethernet controller v Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run the diagnostic programs. Cannot allocate memory for the adapter during an interrupt. Please check your Streams parameters. pnt0-7 Explanation: On a SunSoft Solaris system, this message indicates that the system is out of Streams memory blocks. Action: Use the CRASH utility to increase the number of Streams memory blocks. Modify the interrupt request (IRQ) settings in the Configuration/Setup Utility program, or run the NETCONFIG program to match the hardware settings. Cannot allocate memory for the adapter during reset. Please check your Streams parameters. pnt0-11 Explanation: The system is out of Streams memory blocks. Action: Use the CRASH utility to increase the number of Streams memory blocks. Device not found! pnt0-12 Explanation: The driver cannot find an Ethernet controller. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run the diagnostic programs. Device failed checksum test! pnt0-13 Explanation: The driver cannot find an Ethernet controller. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run the diagnostic programs. add_intr_handler failed! Interrupts already enabled. pnt0-14 Explanation: The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts with other devices in the server. Action: Modify your hardware settings. Cannot locate hardware. pnt0-15 Explanation: The SunSoft Solaris driver cannot find any Ethernet controller. Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is enabled, run the diagnostic programs. No more devices to open. pnt0-17 Explanation: The SunSoft Solaris driver cannot find any more Ethernet controllers. Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic programs. Device fault...Reset initiated! pnt0-19 Explanation: The SunSoft Solaris driver has been reset due to a device fault. Action: Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic programs. IRQ found for PCnet hardware does not match space.c (or pnt.conf)! Explanation: This is a warning message referring to the interrupt request (IRQ) that the SunSoft Solaris driver found in the system. Action: Ignore this message if you are sure that this is what you want to do. Otherwise, run the NETCONFIG program to match the hardware settings Diagnostics 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200

Table
5.
UNIX
LLI
driver
messages
for
the
Ethernet
controller
pnt0-2
PCI
search
specified,
PCI
device
not
found!
Explanation:
The
driver
cannot
locate
the
Ethernet
controller
on
the
PCI
bus.
Action:
v
Run
the
NETCONFIG
program
to
search
for
another
Ethernet
controller
v
Verify
that
the
Ethernet
controller
is
enabled.
If
the
Ethernet
controller
is
enabled,
run
the
diagnostic
programs.
pnt0-6
Cannot
allocate
memory
for
the
adapter
during
an
interrupt.
Please
check
your
Streams
parameters.
Explanation:
On
a
SunSoft
Solaris
system,
this
message
indicates
that
the
system
is
out
of
Streams
memory
blocks.
Action:
Use
the
CRASH
utility
to
increase
the
number
of
Streams
memory
blocks.
Modify
the
interrupt
request
(IRQ)
settings
in
the
Configuration/Setup
Utility
program,
or
run
the
NETCONFIG
program
to
match
the
hardware
settings.
pnt0-7
Cannot
allocate
memory
for
the
adapter
during
reset.
Please
check
your
Streams
parameters.
Explanation:
The
system
is
out
of
Streams
memory
blocks.
Action:
Use
the
CRASH
utility
to
increase
the
number
of
Streams
memory
blocks.
pnt0-11
Device
not
found!
Explanation:
The
driver
cannot
find
an
Ethernet
controller.
Action:
Verify
that
the
Ethernet
controller
is
enabled.
If
the
Ethernet
controller
is
enabled,
run
the
diagnostic
programs.
pnt0-12
Device
failed
checksum
test!
Explanation:
The
driver
cannot
find
an
Ethernet
controller.
Action:
Verify
that
the
Ethernet
controller
is
enabled.
If
the
Ethernet
controller
is
enabled,
run
the
diagnostic
programs.
pnt0-13
add_intr_handler
failed!
Interrupts
already
enabled.
Explanation:
The
interrupt
request
(IRQ)
that
was
specified,
or
the
IRQ
that
was
found,
conflicts
with
other
devices
in
the
server.
Action:
Modify
your
hardware
settings.
pnt0-14
Cannot
locate
hardware.
Explanation:
The
SunSoft
Solaris
driver
cannot
find
any
Ethernet
controller.
Action:
Verify
that
the
Ethernet
controller
is
enabled.
If
the
Ethernet
controller
is
enabled,
run
the
diagnostic
programs.
pnt0-15
No
more
devices
to
open.
Explanation:
The
SunSoft
Solaris
driver
cannot
find
any
more
Ethernet
controllers.
Action:
Verify
that
additional
IBM
Netfinity
10/100
Fault
Tolerant
Adapters
are
present
or
replace
the
Ethernet
adapter
that
fails
to
respond.
If
the
problem
persists,
run
the
diagnostic
programs.
pnt0-17
Device
fault...Reset
initiated!
Explanation:
The
SunSoft
Solaris
driver
has
been
reset
due
to
a
device
fault.
Action:
Verify
that
additional
IBM
Netfinity
10/100
Fault
Tolerant
Adapters
are
present
or
replace
the
Ethernet
adapter
that
fails
to
respond.
If
the
problem
persists,
run
the
diagnostic
programs.
pnt0-19
IRQ
found
for
PCnet
hardware
does
not
match
space.c
(or
pnt.conf)!
Explanation:
This
is
a
warning
message
referring
to
the
interrupt
request
(IRQ)
that
the
SunSoft
Solaris
driver
found
in
the
system.
Action:
Ignore
this
message
if
you
are
sure
that
this
is
what
you
want
to
do.
Otherwise,
run
the
NETCONFIG
program
to
match
the
hardware
settings
Diagnostics
25