IBM 86594RY Hardware Maintenance Manual - Page 172
Remove Failing PCI, Pointing Device
UPC - 087944479673
View all IBM 86594RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 172 highlights
Error Code/Symptom FRU/Action 1806 (PCI to PCI Bridge error) 1. Run Configuration/Setup 2. Move the failing adapter to slot 1 or 2 3. Failing Adapter 4. System Board 1807, 1808, 1810 (General PCI error) 1. Remove Failing PCI Card 2. System Board 1962 (Drive does not contain a valid boot sector) 1. Verify a bootable operating system is installed 2. Run Diagnostics 3. Hard Disk Drive Cable 4. System Board 5. Hard Disk Drive 2400 (Video controller test failure) 1. Video Adapter (if installed) 2. System Board 2462 (Video memory configuration error) 1. Video Adapter (if installed) 2. System Board 5962 (IDE CD-ROM configuration error) 1. Run Configuration/Setup 2. CD-ROM Drive 3. Battery 8603 (Pointing Device Error) 1. Pointing Device 2. System Board 0001200 (Machine check architecture error) 1. Processor 2. Optional Processor 000120P0, 000120P1,000120P2,000120PF (Processor cache error) 1. Failing Processor 01295085 (ECC checking hardware test error) 1. Processor I9990301 (Fixed boot sector error, no operating system installed) 1. Run Configuration/Setup for correct startup 2. Verify operating system installed I9990305 (Fixed boot sector error, no operating system installed) 1. Install operating system to hard disk drive. I9990650 (AC power has been restored) 1. Check cable 2. Check for interruption of power supply 3. Power Cable 164 Netfinity Server HMM