Icom IC-M330G Instruction Manual english - Page 55
Data Output, Alarm Status, CH 70 SQL Level, Safety, Routine, Warning, Self-Terminate, Discrete
View all Icom IC-M330G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
DSC OPERATION 7 Data Output (Default: Off) When receiving a DSC call from the station that is selected in this setting, the transceiver outputs the DSC data to the NMEA output port. LLYou can send Distress calls despite of this setting. All Stations: From any station. Stations List: From the stations that are entered Individual ID or Group ID on the Menu screen. OFF: Does not output any DSC data from the NMEA 0183 Output port. Alarm Status Set the alarm ON or OFF for each DSC related item. ••Safety (Default: On) An alarm sounds when a Safety DSC call is received. ••Routine (Default: On) An alarm sounds when a Routine DSC call is received. 1 ••Warning An alarm sounds when: (Default: On) 2 3 - No MMSI code is entered. - The position data has not been received for 2 minutes 4 after turning ON the transceiver. 5 - The received position data has not been updated for 10 minutes. 6 - The received position data has not been updated for 4 7 hours. - The manually entered position data has not been updated 8 for 23.5 hours. 9 ••Self-Terminate (Default: On) 10 An alarm sounds when duplicate DSC calls are received. 11 ••Self-Terminate (Default: On) 12 An alarm sounds when duplicate Distress calls are received. 13 14 ••Discrete (Default: On) An alarm sounds when a lower priority call is received 15 while receiving a high priority call. 16 CH 70 SQL Level (Default: 3) Adjust the Squelch level for Channel 70 to between 1 and 10, or Open. 43