Icom IC-R8600 I/q Output Reference Guide - Page 11

■Control commands relative to I/Q port setting, Receive frequency, Receive Band edge frequency

Page 11 highlights

I/Q SIGNAL ■■Control commands relative to I/Q port setting DDReceive frequency Command: 05 q XX w XX e XX r XX t XX 10Hz d ig it : 0 ~ 9 1Hz d ig it : 0 ~ 9 1kHz d ig it : 0 ~ 9 100Hz d ig it : 0 ~ 9 100kHz d ig it : 0 ~ 9 10kHz d ig it : 0 ~ 9 10MHz d ig it : 0 ~ 9 1MHz d ig it : 0 ~ 9 1GHz d ig it : 0 ~ 3 100MHz d ig it : 0 ~ 9 LYou can omit the upper digits entry. When omitted, the current frequency is applied. DDReceive Band edge frequency Command: 1A 0F PC to IC-R8600 (Write data format) Specify the band edge to read by the edge number in a BCD code. q XX Edge number: 01 to XX* LThe upper number (*marked) will be the returned value of command "1A 0E." LIf the specified number exceeds the readable capacity, "NG (FA)" will be returned. To read the number of the edge, send command "1A 0E" (The Read Receive Band Edge Count command). IC-R8600 to PC (Read data format) q w e r t y u i o !0 !1 !2 XX XXXXXXXXXX 2 DXXXXXXXXXX Edge number 01~XX* 10 Hz digit: 0 ~ 9 1 Hz digit: 0 ~ 9 1 kHz digit: 0 ~ 9 100 Hz digit: 0 ~ 9 100 kHz digit: 0 ~ 9 10 kHz digit: 0 ~ 9 10 MHz digit: 0 ~ 9 1 MHz digit: 0 ~ 9 1 GHz digit: 0 ~ 3 100 MHz digit: 0 ~ 9 Separator (Fixed) 10 Hz digit: 0 ~ 9 1 Hz digit: 0 ~ 9 1 kHz digit: 0 ~ 9 100 Hz digit: 0 ~ 9 100 kHz digit: 0 ~ 9 10 kHz digit: 0 ~ 9 10 MHz digit: 0 ~ 9 1 MHz digit: 0 ~ 9 1 GHz digit: 0 ~ 3 100 MHz digit: 0 ~ 9 Edge frequency (Lower) Edge frequency (Upper) LThe upper number (*marked) will be the returned value of command "1A 0E." LThe lower edge frequency, separator (fixed to "2D") and upper edge frequency are returned as well as the Edge number. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Control commands relative to I/Q port setting
D
Receive frequency
Command:
05
q
w
e
r
t
10Hz digit:
0 ~ 9
1Hz digit:
0 ~ 9
1kHz digit:
0 ~ 9
100Hz digit:
0 ~ 9
100kHz digit: 0 ~ 9
10kHz digit:
0 ~ 9
10MHz digit: 0 ~ 9
1MHz digit:
0 ~ 9
1GHz digit:
0 ~ 3
100MHz digit: 0 ~ 9
X
X
X
X
X
X
X
X
X
X
L
You can omit the upper digits entry. When omitted, the current frequency is applied.
D
Receive Band edge frequency
Command:
1A 0F
PC to IC-R8600 (Write data format)
Specify the band edge to read by the edge number in a BCD code.
q
Edge number: 01 to XX*
XX
L
The upper number (*marked) will be the returned value of command “1A 0E.”
L
If the specified number exceeds the readable capacity, “NG (FA)” will be returned.
To read the number of the edge, send command “1A 0E” (The Read Receive Band Edge Count command).
IC-R8600 to PC (Read data format)
q
w
e
r
t
y
u
i
o
!0
!1
!2
XX
XX
XXXXXXXX2DXXXXXXXXXX
Edge frequency (Lower)
Edge frequency (Upper)
Separator (Fixed)
10 Hz digit:
0 ~ 9
1 Hz digit:
0 ~ 9
1 kHz digit:
0 ~ 9
100 Hz digit:
0 ~ 9
100 kHz digit: 0 ~ 9
10 kHz digit:
0 ~ 9
10 MHz digit: 0 ~ 9
1 MHz digit:
0 ~ 9
1 GHz digit:
0 ~ 3
100 MHz digit: 0 ~ 9
10 Hz digit:
0 ~ 9
1 Hz digit:
0 ~ 9
1 kHz digit:
0 ~ 9
100 Hz digit:
0 ~ 9
100 kHz digit: 0 ~ 9
10 kHz digit:
0 ~ 9
10 MHz digit: 0 ~ 9
1 MHz digit:
0 ~ 9
1 GHz digit:
0 ~ 3
100 MHz digit: 0 ~ 9
Edge number 01~XX*
L
The upper number (*marked) will be the returned value of command “1A 0E.”
L
The lower edge frequency, separator (fixed to “2D”) and upper edge frequency are returned as well as the Edge number.
I/Q SIGNAL
10