Icom IC-R8600 I/q Output Reference Guide - Page 3
I/Q SIGNAL, ■General - software
View all Icom IC-R8600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
I/Q SIGNAL ■■General DDGeneral description You can get I/Q signals from the [I/Q OUT] port on the IC-R8600 by connecting the IC-R8600 and a PC, with a USB cable. You can receive I/Q signals and control the IC-R8600, through the USB cable. [I/Q OUT]port IC-R8600 (Ver.1.30 or later) USB cable • I/Q data • Control command [USB]port (USB3.0/USB2.0) Driver PC Windows 10 Windows 8.1 Windows 7 (32/64 bit) (32/64 bit) (32/64 bit) Requirement: ••IC-R8600 firmware must be version 1.3 or later. ••Windows 7 /8.1/10 PC (32 bit or 64 bit) ••USB 2.0 or higher ••USB I/Q driver (USB I/Q Package for HDSDR) You can download it from the Icom web site. (The software is commonly used with HDSDR*.) *An SDR receive software (freeware). You can download it from: http://www.hdsdr.de/ I/Q signal specifications: Sampling frequency Bit depth 16-bit 24-bit 5.12 MHz Yes N/A 3.84 MHz Yes Yes 1.92 MHz Yes Yes 960 kHz 480 kHz Yes Yes Yes Yes 240 kHz Yes Yes Signal Bandwidth 4.48 MHz 3.31 MHz 1.63 MHz 815 kHz 408 kHz 203 kHz 2