Icom IC-R8600 I/q Output Reference Guide - Page 12

DI/Q Output setting, 1A 13 01, PC to IC-R8600 Write data format

Page 12 highlights

I/Q SIGNAL ■■ Control commands relative to I/Q port setting (Continued) DDI/Q Output setting Command: 1A 13 01 PC to IC-R8600 (Write data format): Sets the I/Q output setting to ON or OFF. • Turning OFF the I/Q signal output I/Q output setting 00 0 = OFF 0 (Fixed) • Turning ON the I/Q signal output Also sends the bit depth and sampling frequency data. I/Q output setting Sampling frequency 010X0X 0 (Fixed) Bit depth 1 = ON You can set the I/Q signal output setting by sending the command through the [I/Q OUT] port. Only when the I/Q mode is set to "ON," you can set the I/Q output to ON. When the sent command is valid and accepted by the IC-R8600, the acknowledgement "OK (FB)" will be returned. "NG (FA)" will be returned if invalid. I/Q Output Bit depth Sampling frequency 00: OFF 01: ON - 00: 16-bit 01: 24-bit - 01 5.12 MHz 04 960 kHz 02 3.84 MHz 05 480 kHz 03 1.92 MHz 06 240 kHz NOTE: The combination of 5.12 MHz and 24 bit is invalid, and "NG (FA)" will be returned. 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

D
I/Q Output setting
Command:
1A 13 01
PC to IC-R8600 (Write data format):
Sets the I/Q output setting to ON or OFF.
• Turning OFF the I/Q signal output
I/Q output setting
0=OFF
0 (Fixed)
00
• Turning ON the I/Q signal output
Also sends the bit depth and sampling frequency data.
I/Q output setting
Sampling frequency
Bit depth
1=ON
0 (Fixed)
0X0X
01
You can set the I/Q signal output setting by sending the command through the [I/Q OUT] port.
Only when the I/Q mode is set to “ON,” you can set the I/Q output to ON.
When the sent command is valid and accepted by the IC-R8600, the acknowledgement “OK (FB)” will be
returned. “NG (FA)” will be returned if invalid.
I/Q Output
Bit depth
Sampling frequency
00: OFF
00: 16-bit
01
5.12 MHz
04
960 kHz
01: ON
01: 24-bit
02
3.84 MHz
05
480 kHz
03
1.92 MHz
06
240 kHz
NOTE:
The combination of 5.12 MHz and 24 bit is invalid, and “NG (FA)” will be returned.
Control commands relative to I/Q port setting (Continued)
I/Q SIGNAL
11