Insignia NS-FDRE80W3 User Manual - Page 22

Insert the elbow/duct assembly through the side opening and press it onto

Page 22 highlights

INSTALLATION INSTRUCTIONS 1 Remove the two rear exhaust retaining screws, then pull out the exhaust duct. Retaining screw Rear exhaust duct 2 Press the tabs on the knockout, then carefully remove the knockout for the desired vent opening. 3 Push the adapter duct onto the blower housing of your dryer. Adapter duct Blower housing DRYER SIDE/BACK VIEW Knockout 4 Connect a 4 in. (10.2cm) elbow to the 4 in. (10.2cm) duct section, and secure all joints with duct tape. Make sure that the male end of the elbow faces away from your dryer. 5 Insert the elbow/duct assembly through the side opening and press it onto the adapter duct. Secure in place with duct tape. The male end of the duct should protrude 1.5 in. (3.8 cm) out of your dryer to connect the remaining ductwork. 6 Attach duct tape to the back of your dryer to seal the original dryer vent hole. Duct tape Elbow 1 1/2 in. (3.8 cm) 22 www.insigniaproducts.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

22
www.insigniaproducts.com
INSTALLATION INSTRUCTIONS
1
Remove the two rear exhaust retaining screws, then pull out the exhaust duct.
2
Press the tabs on the knockout, then carefully remove the knockout for the
desired vent opening.
3
Push the adapter duct onto the blower housing of your dryer.
4
Connect a 4 in. (10.2cm) elbow to the 4 in. (10.2cm) duct section, and secure
all joints with duct tape. Make sure that the male end of the elbow faces away
from your dryer.
5
Insert the elbow/duct assembly through the side opening and press it onto
the adapter duct. Secure in place with duct tape. The male end of the duct
should protrude 1.5 in. (3.8 cm) out of your dryer to connect the remaining
ductwork.
6
Attach duct tape to the back of your dryer to seal the original dryer vent hole.
Retaining screw
Rear exhaust duct
Adapter duct
Knockout
DRYER SIDE/BACK VIEW
Blower housing
Elbow
Duct tape
1 1/2 in. (3.8 cm)