Insignia NS-FDRE80W3 User Manual - Page 49
Understanding the error codes, Specifications
View all Insignia NS-FDRE80W3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
USER MAINTENANCE INSTRUCTIONS 8 Cu. Ft. Electric and Gas Dryers Understanding the error codes Your dryer is equipped with an automatic error-monitoring system to detect and diagnose problems at an early stage. When an error occurs, your dryer beeps for five seconds every 15 minutes. ERROR CODE C9 E4 E5 POSSIBLE CAUSE The PCB failed. The humidity sensor failed. The temperature sensor failed. SOLUTIONS Call customer service for help. Do not use your dryer. Your dryer will complete the current operating cycle but garments could be over dried. Your dryer can still operate using the Time Dry cycles. Call the service center for help. Call customer service for help. Do not use your dryer. Specifications Dimensions (H × W × D) Weight Capacity Power Heating rating Noise level 39 13/16 × 27 × 33 3/4 in (101.1 × 68.6 × 85.6 cm) Net: 132 5/16 lbs. (60 kg) Gross: 147 3/4 lbs. (67 kg) 8 cu. ft. Electric: 120/240V Gas: 120V Electric: 5,200W Gas: 20,000 BTU/hr 69 dB www.insigniaproducts.com 49