INSTALLATION INSTRUCTIONS 8 Cu. Ft. Electric and Gas Dryers Materials you will need • 3/8" gas dryer gas line (gas model only) • Three- or four-prong (dependent on owner's house) electric power cord (electric model only) • Exhaust dryer vent kit Before you start Before you start installing your dryer, make sure that: • The location you selected has a grounded electrical outlet. See Grounding requirements on page 20. • You have the correct type of power cord. The power cord is not included with electric dryers. Gas dryers include a power cord. See "Electric requirements" on page 17. • Your dryer vent is in the correct location. See "Changing the dryer vent location (optional)" on page 21 to change where your dryer vents. • Your exhaust ducting (not included) is made of rigid metal or semi-rigid metal. See Duct requirements on page 16. • You have a 3/8 in. (1 cm) gas dryer gas line (if you are installing a gas dryer) that meets all national and local codes. Before you connect the gas line, review the gas line requirements in Gas requirements on page 19. www.insigniaproducts.com 25