Four-wire outlet - for electric dryers

Page 31 highlights

INSTALLATION INSTRUCTIONS 8 Cu. Ft. Electric and Gas Dryers 3 Connect the other wires to the outer terminal block screws. Be sure to cross the screw through the terminal ring and tighten the screw. 4 Tighten the strain relief screws. 5 Insert the tab of the terminal block cover into your dryer's rear panel slot, then secure the cover with a screw. WARNING: If your are converting from a four-wire electrical system to a three-wire, you must reconnect the ground strap to the terminal block support to ground the dryer frame to the neutral conductor. Ring-type terminals are recommended. If using strap terminals, make sure that they are tightened. Four-wire outlet - for electric dryers: Center terminal block screw Black wire External ground connector Green or bare copper wire of the power cord Neutral grounding wire (white) Red wire Neutral wire (white or center wire) 3/4" (1.9 cm) UL-listed strain relief 1 Remove the center terminal block screw. 2 Connect the ground wire (green or unwrapped) of the power cord to the external ground conductor screw. 3 Connect the neutral wire (white wire) of the power cord and the appliance ground wire (white) under the center screw of the terminal block. Be sure to cross the screw through the ring of the power cord terminal and tighten the screw. 4 Connect the other wires to the outer terminal block screws. Be sure to cross the screw through the terminal ring and tighten the screw. 5 Tighten the strain relief screws. www.insigniaproducts.com 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

31
www.insigniaproducts.com
8 Cu. Ft. Electric and Gas Dryers
INSTALLATION INSTRUCTIONS
3
Connect the other wires to the outer terminal block screws. Be sure to cross
the screw through the terminal ring and tighten the screw.
4
Tighten the strain relief screws.
5
Insert the tab of the terminal block cover into your dryer’s rear panel slot, then
secure the cover with a screw.
Four-wire outlet - for electric dryers:
1
Remove the center terminal block screw.
2
Connect the ground wire (green or unwrapped) of the power cord to the
external ground conductor screw.
3
Connect the neutral wire (white wire) of the power cord and the appliance
ground wire (white) under the center screw of the terminal block. Be sure to
cross the screw through the ring of the power cord terminal and tighten the
screw.
4
Connect the other wires to the outer terminal block screws. Be sure to cross
the screw through the terminal ring and tighten the screw.
5
Tighten the strain relief screws.
WARNING:
If your are converting from a four-wire electrical system to a
three-wire, you must reconnect the ground strap to the terminal block support
to ground the dryer frame to the neutral conductor. Ring-type terminals are
recommended. If using strap terminals, make sure that they are tightened.
Center terminal block screw
Black wire
External ground connector
Green or bare copper
wire of the power cord
Red wire
Neutral wire (white or
center wire)
3/4" (1.9 cm) UL-listed
strain relief
Neutral grounding wire
(white)