Intel SE7501CW2 Product Guide - Page 46

Changing the BIOS Language, Hardware Monitoring - cpu support

Page 46 highlights

Changing the BIOS Language You can use the BIOS upgrade utility to change the language the BIOS uses for messages and the Setup program. Use a bootable diskette containing the Intel flash utility and language files. 1. Boot the computer with the bootable diskette in drive A. The BIOS upgrade utility screen appears. 2. Select Update Flash Memory From a File. 3. Select Update Language Set. Press . 4. Select drive A and use the arrow keys to select the correct .lng file. Press . 5. When the utility asks for confirmation that you want to flash the new language into memory, select Continue with Programming. Press . 6. When the utility displays the message upgrade is complete, remove the diskette. Press . 7. The computer will reboot and the changes will take effect. Hardware Monitoring The Server Board SE7501CW2 has an integrated Winbond Heceta* 836327HF chip that is responsible for hardware monitoring. Together, the Winbond Heceta chip and LANDesk* Client Manager (LDCM) 6.3 software provide basic server hardware monitoring that alerts a system administrator if a hardware problem occurs on an Intel Server Board SE7501CW2-based system. The LANDesk Client Manager software is for use with Windows 2000 Server and Windows 2000 Advanced Server operating systems. Other operating systems supported by the Server Board SE7501CW2 such as Windows XP, NetWare 6.0, or Red Hat* Linux* will not be monitored with the LANDesk Client Manager software. Table 26 lists the monitored headers and sensors on the Server Board SE7501CW2. Table 26. Monitored Headers and Sensors Sensor Type Item Description Voltage CPU1/2 Monitors processor voltage (one CPU power plane) 1.8 V Chipset VCC3 Monitors VCC3 VCC Monitors VCC +12 V Monitors +12 V 2.5 V Monitors 2.5 V (for DIMM) Vbat Battery pin voltage 5 VSB Monitors 5 VSB (5 V stand-by) Fan Speed CPU1_FAN Monitors primary processor fan speed CPU2_FAN Monitors secondary processor fan speed CHASSIS_FAN Monitors chassis fan speed through chassis fan header 3 only. (Total four chassis fans available) Temperature CPU2 Monitors primary processor temperature CPU1 Monitors secondary processor temperature CHASSIS Monitors chassis ambient temperature 46 Intel Server Board SE7501CW2 Product Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93

46
Intel Server Board SE7501CW2 Product Guide
Changing the BIOS Language
You can use the BIOS upgrade utility to change the language the BIOS uses for messages and the
Setup program.
Use a bootable diskette containing the Intel flash utility and language files.
1.
Boot the computer with the bootable diskette in drive A.
The BIOS upgrade utility screen
appears.
2.
Select Update Flash Memory From a File.
3. Select Update
Language Set.
Press <Enter>.
4.
Select drive A and use the arrow keys to select the correct
.
lng file.
Press <Enter>.
5.
When the utility asks for confirmation that you want to flash the new language into memory,
select Continue with Programming.
Press <Enter>.
6.
When the utility displays the message upgrade is complete, remove the diskette.
Press
<Enter>.
7.
The computer will reboot and the changes will take effect.
Hardware Monitoring
The Server Board SE7501CW2 has an integrated Winbond Heceta
*
836327HF chip that is
responsible for hardware monitoring.
Together, the Winbond Heceta chip and LANDesk
*
Client
Manager (LDCM) 6.3 software provide basic server hardware monitoring that alerts a system
administrator if a hardware problem occurs on an Intel Server Board SE7501CW2–based system.
The LANDesk Client Manager software is for use with Windows 2000 Server and Windows 2000
Advanced Server operating systems.
Other operating systems supported by the Server Board
SE7501CW2 such as Windows XP, NetWare 6.0, or Red Hat
*
Linux
*
will not be monitored with
the LANDesk Client Manager software.
Table 26 lists the monitored headers and sensors on the
Server Board SE7501CW2.
Table 26.
Monitored Headers and Sensors
Sensor Type
Item
Description
Voltage
CPU1/2
Monitors processor voltage (one CPU power plane)
1.8 V
Chipset
VCC3
Monitors VCC3
VCC
Monitors VCC
+12 V
Monitors +12 V
2.5 V
Monitors 2.5 V (for DIMM)
Vbat
Battery pin voltage
5 VSB
Monitors 5 VSB (5 V stand-by)
Fan Speed
CPU1_FAN
Monitors primary processor fan speed
CPU2_FAN
Monitors secondary processor fan speed
CHASSIS_FAN
Monitors chassis fan speed through chassis fan header
3 only.
(Total four chassis fans available)
Temperature
CPU2
Monitors primary processor temperature
CPU1
Monitors secondary processor temperature
CHASSIS
Monitors chassis ambient temperature