Intel SR1550ALSAS User Guide - Page 29
Recovery Jumpers
View all Intel SR1550ALSAS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
BMC Force Update Mode 2 3 J1D2 Password Reset Disable 2 Enable 3 J1D1 2 Clear 3 CMOS J1D3 TP02080 Jumper Name Jumper Purpose CMOS Clear If pins 2-3 are jumpered, the CMOS settings will be cleared on the next reset. These pins should be jumpered on 1-2 for normal operation. Password Clear If pins 2-3 are jumpered, administrator and user passwords will be cleared on the next reset. These pins should be jumpered on 1-2 for normal operation. BMC Force Update Mode If pins 2-3 are jumpered, BMC Force Update Mode is enabled. These pins should be jumpered on 1-2 for normal operation. Figure 5. Recovery Jumpers Intel® Server System SR1550AL/SR1550ALSAS User's Guide 9
Intel
®
Server System SR1550AL/SR1550ALSAS User’s Guide
9
Figure 5. Recovery Jumpers
Jumper Name
Jumper Purpose
CMOS Clear
If pins 2-3 are jumpered, the CMOS settings will be cleared on the
next reset. These pins should be jumpered on 1-2 for normal
operation.
Password Clear
If pins 2-3 are jumpered, administrator and user passwords will be
cleared on the next reset. These pins should be jumpered on 1-2 for
normal operation.
BMC Force Update Mode
If pins 2-3 are jumpered, BMC Force Update Mode is enabled.
These pins should be jumpered on 1-2 for normal operation.
TP02080
3
2
Password
Reset
J1D2
J1D3
3
2
Clear
CMOS
BMC Force
Update Mode
3
2
J1D1
Disable
Enable