Intel SR1550ALSAS User Guide - Page 93

Removing and Installing the Fan Pack

Page 93 highlights

7. With the fan oriented correctly, insert the fan into the fan module as shown in the figure below (see letter "A"). 8. Connect the fan cable to the connector on the mid-plane board as shown in the figure below (see letter "B"). B A TP02267 Figure 66. Installing a System Fan 9. Install the server system cover. For instructions, see "Installing the Server System Cover". 10. Plug all peripheral devices and the AC power cable into the server. Removing and Installing the Fan Pack Removing the Fan Pack 1. Observe the safety and ESD precautions at the beginning of this book. See "Safety Information". 2. Power down the server and unplug all peripheral devices and the AC power cable. 3. Remove the server system cover. For instructions, see "Removing the Chassis Cover". 4. Remove the processor air duct. For instructions, see "Removing the Processor Air Duct". 5. Remove the power distribution board cover. For instructions, see "Replacing the Power Distribution Module". 6. Disconnect the IDE cable from the backplane. 7. Remove the bridge board. Intel® Server System SR1550AL/SR1550ALSAS User's Guide 73

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

Intel
®
Server System SR1550AL/SR1550ALSAS User’s Guide
73
7.
With the fan oriented correctly, insert the fan into the fan module as shown in the
figure below (see letter “A”).
8.
Connect the fan cable to the connector on the mid-plane board as shown in the
figure below (see letter “B”).
Figure 66. Installing a System Fan
9.
Install the server system cover. For instructions, see
“Installing the Server System
Cover”
.
10.
Plug all peripheral devices and the AC power cable into the server.
Removing and Installing the Fan Pack
Removing the Fan Pack
1.
Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information”
.
2.
Power down the server and unplug all peripheral devices and the AC power cable.
3.
Remove the server system cover. For instructions, see
“Removing the Chassis
Cover”
.
4.
Remove the processor air duct. For instructions, see
“Removing the Processor Air
Duct”
.
5.
Remove the power distribution board cover. For instructions, see
“Replacing the
Power Distribution Module”
.
6.
Disconnect the IDE cable from the backplane.
7.
Remove the bridge board.
A
B
TP02267