Intel SSR212CC User Guide - Page 112

Removing or Installing the Intel® Management Module Professional (IMM Pro) Module

Page 112 highlights

Hardware Installations and Upgrades 8. Reinstall the processor duct. For instructions, see "Installing the Processor Air Duct" on page 73. 9. Install the enclosure cover. For instructions, see "Installing the Enclosure Cover" on page 16. 10. Re-connect all peripheral devices and the AC power cable. Power up the storage system. Removing or Installing the Intel® Management Module Professional (IMM Pro) Module Removing the IMM Pro Module Caution: Before performing any maintenance on the system, back up the data. Follow the instructions in the operating system manual for shutting down the system. Caution: Before installing an IMM Pro module, ensure that the module has the correct firmware version installed. This may require setting up the module in an external system (with a CD-ROM or floppy drive) and updating with the appropriate firmware version. Refer to the Intel® Storage System SSR212CC Tested Hardware and Operating System List for the tested firmware version. Refer to the support site at http://www.intel.com/support/ motherboards/server/ism for the appropriate firmware and documentation to download. 1. Observe all safety and ESD precautions listed in Appendix D, "Safety Information". 2. Turn off all peripheral devices connected to the storage system. Turn off the storage system. 3. Disconnect the AC power cord(s). 4. Remove the enclosure cover. For instructions, see "Removing the Enclosure Cover" on page 14. 94 Intel® Storage System SSR212CC User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202

Hardware Installations and Upgrades
94
Intel® Storage System SSR212CC User Guide
8.
Reinstall the processor duct. For instructions, see
“Installing the Processor Air Duct”
on page 73
.
9.
Install the enclosure cover. For instructions, see
“Installing the Enclosure Cover” on
page 16
.
10. Re-connect all peripheral devices and the AC power cable. Power up the storage
system.
Removing or Installing the Intel® Management Module
Professional (IMM Pro) Module
Removing the IMM Pro Module
Caution:
Before performing any maintenance on the system, back up the data. Follow the
instructions in the operating system manual for shutting down the system.
Caution:
Before installing an IMM Pro module, ensure that the module has the correct firmware
version installed. This may require setting up the module in an external system (with a
CD-ROM or floppy drive) and updating with the appropriate firmware version. Refer to
the Intel® Storage System SSR212CC Tested Hardware and Operating System List for the
tested firmware version. Refer to the support site at http://www.intel.com/support/
motherboards/server/ism for the appropriate firmware and documentation to download.
1.
Observe all safety and ESD precautions listed in
Appendix D, “Safety Information”
.
2.
Turn off all peripheral devices connected to the storage system. Turn off the storage
system.
3.
Disconnect the AC power cord(s).
4.
Remove the enclosure cover. For instructions, see
“Removing the Enclosure Cover”
on page 14
.