10.2 Troubleshooting: Mechanical SYMPTOM PROBABLE CAUSE Bed does not stay in place. Locking casters not locked. Bed sections do not move. Pull tube Bed ends move in opposite directions (electrical or manual bed). Hi/Lo function does not work. Drive shaft connected to wrong gear box shaft. Drive shaft disconnected. Pressing function on pendant results in Motor cable connections to junction motion other than that intended. box incorrect. 10 TROUBLESHOOTING SOLUTIONS Lock casters. Refer to Installing Casters on page 35. Ensure pull tubes are properly connected. Refer to FIGURE 11. Check pull tube(s) for binding. Call dealer for repairs. Reinstall drive shaft. Refer to Assembling/Installing/Removing Drive Shaft on page 40. Reinstall drive shaft. Refer to Assembling/Installing/Removing Drive Shaft on page 40. Verify connections. Refer to FIGURE 11. Part No 1123842 51 Invacare®IVC™Model BAR600IVC Bariatric Bed
-