Invacare M91 Owners Manual - Page 68

Electronics

Page 68 highlights

SECTION 12-ELECTRONICS SECTION 12-ELECTRONICS ƽ WARNING After any adjustments, repair or service and before use, make sure that all attaching hardware is tightened securely - otherwise injury or damage may result. Before performing any maintenance, adjustment or service verify that On/Off switch on the joystick is in the Off position. Repositioning the Joystick NOTE: For this procedure, refer to FIGURE 12.1. NOTE: Take note of position and orientation of mounting hardware for reinstalling the joystick assembly. 1. Turn the adjustment lock lever to release the joystick mounting tube from the mounting bracket. 2. Remove the joystick from the wheelchair. 3. Remove the three hex mounting screws, spacers and locknuts that secure the mounting bracket to the three mounting holes on the arm frame. NOTE: The mounting bracket is mounted to the inside of the arm frame. 4. Reposition the mounting bracket on the opposite arm frame. 5. Using the three hex mounting screws, spacers and locknuts secure the mounting bracket to the three mounting holes of the arm frame. 6. If necessary, perform the following to reposition the adjustment lock: A. Slide the adjustment lock from the mounting bracket. B. Rotate adjustment lock 180° and slide adjustment lock over the opposite end of the mounting bracket. 7. Slide joystick mounting tube through the mounting bracket to the desired position and secure adjustment lock to tube by turning lever on adjustment lock. NOTE: Joystick not shown. Locknuts Arm Frame Hex Mounting Screws Adjustment Lock Lever Mounting Bracket Spacers FIGURE 12.1 Repositioning the Joystick Joystick Mounting Tube Pronto® M91™ with SureStep® 68 Part No 1141450

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

SECTION 12—ELECTRONICS
Pronto® M91™ with SureStep®
68
Part No 1141450
SECTION 12—ELECTRONICS
±
WARNING
After any adjustments, repair or service and before use, make sure that all attaching
hardware is tightened securely - otherwise injury or damage may result.
Before performing any maintenance, adjustment or service verify that On/Off
switch on the joystick is in the Off position.
Repositioning the Joystick
NOTE: For this procedure, refer to FIGURE 12.1.
NOTE: Take note of position and orientation of mounting hardware for reinstalling the joystick
assembly.
1.
Turn the adjustment lock lever to release the joystick mounting tube from the
mounting bracket.
2.
Remove the joystick from the wheelchair.
3.
Remove the three hex mounting screws, spacers and locknuts that secure the
mounting bracket to the three mounting holes on the arm frame.
NOTE: The mounting bracket is mounted to the inside of the arm frame.
4.
Reposition the mounting bracket on the opposite arm frame.
5.
Using the three hex mounting screws, spacers and locknuts secure the mounting
bracket to the three mounting holes of the arm frame.
6.
If necessary, perform the following to reposition the adjustment lock:
A. Slide the adjustment lock from the mounting bracket.
B. Rotate adjustment lock 180° and slide adjustment lock over the opposite end of the
mounting bracket.
7.
Slide joystick mounting tube through the mounting bracket to the desired position
and secure adjustment lock to tube by turning lever on adjustment lock.
FIGURE 12.1
Repositioning the Joystick
Hex Mounting Screws
Locknuts
Adjustment Lock Lever
Joystick Mounting
Tube
Mounting
Bracket
Spacers
Arm Frame