Invacare TRSX52FBP User Manual - Page 55
Front Casters
View all Invacare TRSX52FBP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
9 Front Casters 9 FRONT CASTERS ƽ WARNING After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely - otherwise injury or damage may occur. 9.1 Installing/Replacing Six/Eight Inch Front Casters/Forks ƽ WARNING Make sure both fork/caster assemblies are the same size before using the wheelchair, otherwise injury may occur. This procedure can be performed if replacing the exact same size front caster. 1. Remove the dust cover. 2. Remove the locknut and nylon washer that secures the fork to the caster headtube. 3. Drop the fork assembly out of the caster headtube. If caster tire/tube replacement is desired, refer to Replacing/Repairing Caster Tire/Tube on page 33. 4. Slide the new fork assembly into the caster headtube. 5. Reassemble by reversing STEPS 1-3. 6. Repeat STEPS 1-5 for the opposite fork assembly. 7. Adjust the forks. Refer to Adjusting Forks on page 56. Non-recliner Wheelchairs under 20 Inches Wide Non-recliner Wheelchairs under 20 to 22 Inches Wide and recliner models Dust Cover Locknut Nylon Washer Caster Headtube Fork Stem Washer Fork Assembly FIGURE 1 Installing/Replacing Six/Eight Inch Front Casters/Forks Part No. 1110550 55 Invacare® Tracer® SX5 Wheelchair