Alarm Output Terminal, This terminal is for connecting with an alarm annunciator such as an indicator

Page 17 highlights

1-4 Connecting the Alarm I/O Terminals (continued) Alarm Output Terminal This terminal is for connecting with an alarm annunciator such as an indicator, a lamp or a buzzer. VN-C11 Output terminal MAX 300 mA COM terminal Grounding terminal (Alarm output equivalent circuit) IN MAX 12 V COM GND IN COM Annunciator Connection Example 1 DC 12 V R Annunciator Connection Example 2 DC R 12 V Buzzer, lamp, LED etc. Output Requirements • Equivalent to NPN open collector output (The output logic is set with [V.Networks Setup Tool.]) • Allowed applied voltage: DC 12 V max. • Allowed input current: 300 mA • Momentary output: 2 to 5000 ms (The duration is set with [V.Networks Setup Tool.]) Caution Connect the VN-C11 grounding terminal to the one of the annunciator. GND Annunciator Connection Example 3 DC R 12 V Buzzer, lamp, LED etc. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

17
This terminal is for connecting with an alarm annunciator such as an indicator, a
lamp or a buzzer.
1-4 Connecting the Alarm I/O Terminals (continued)
Alarm Output Terminal
Output Requirements
Equivalent to NPN open collector output
(The output logic is set with [V.Networks Setup
Tool.])
Allowed applied voltage: DC 12 V max.
Allowed input current: 300 mA
Momentary output: 2 to 5000 ms
(The duration is set with [V.Networks Setup
Tool.])
VN-C11
Annunciator
Connection
Example 1
Output
terminal
IN
R
DC 12 V
(Alarm output equivalent circuit)
COM
terminal
COM
Grounding
terminal
GND
MAX
300 mA
MAX
12 V
Annunciator
Connection
Example 2
IN
R
DC
12 V
COM
GND
Buzzer, lamp, LED etc.
Annunciator
Connection
Example 3
R
DC
12 V
Buzzer, lamp, LED etc.
Caution
Connect the VN-C11 grounding terminal to
the one of the annunciator.