JVC VN-C655U Instructions - Page 19

Alarm Output Terminal - setup tool

Page 19 highlights

8. Alarm Output Terminal This terminal is for connecting with an alarm annunciator such as an indicator, a lamp or a buzzer. VN-C655 Output terminal Annunciator Connection Example DC 12 V IN R Grounding terminal (Alarm output equivalent circuit) GND Output Requirements • Equivalent to NPN open collector output (The output logic is set with [V.Networks Setup Tool.]) • Allowed applied voltage: DC 12 V max. • Allowed input current: 50 mA • Momentary output: 1 to 5000 ms (The duration is set with [V.Networks Setup Tool.]) Caution Connect the VN-C655 grounding terminal to the one of the annunciator. 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

19
This terminal is for connecting with an alarm annunciator such as an indicator, a
lamp or a buzzer.
8. Alarm Output Terminal
Output Requirements
Equivalent to NPN open collector output
(The output logic is set with [V.Networks Setup
Tool.])
Allowed applied voltage: DC 12 V max.
Allowed input current: 50 mA
Momentary output: 1 to 5000 ms
(The duration is set with [V.Networks Setup
Tool.])
VN-C655
Annunciator
Connection
Example
Output
terminal
IN
R
DC 12 V
(Alarm output equivalent circuit)
Grounding
terminal
GND
Caution
Connect the VN-C655 grounding terminal
to the one of the annunciator.