8. Alarm Output Terminal This terminal is for connecting with an alarm annunciator such as an indicator, a lamp or a buzzer. VN-C655 Output terminal Annunciator Connection Example DC 12 V IN R Grounding terminal (Alarm output equivalent circuit) GND Output Requirements • Equivalent to NPN open collector output (The output logic is set with [V.Networks Setup Tool.]) • Allowed applied voltage: DC 12 V max. • Allowed input current: 50 mA • Momentary output: 1 to 5000 ms (The duration is set with [V.Networks Setup Tool.]) Caution Connect the VN-C655 grounding terminal to the one of the annunciator. 19
19
This terminal is for connecting with an alarm annunciator such as an indicator, a
lamp or a buzzer.
8. Alarm Output Terminal
Output Requirements
•
Equivalent to NPN open collector output
(The output logic is set with [V.Networks Setup
Tool.])
•
Allowed applied voltage: DC 12 V max.
•
Allowed input current: 50 mA
•
Momentary output: 1 to 5000 ms
(The duration is set with [V.Networks Setup
Tool.])
VN-C655
Annunciator
Connection
Example
Output
terminal
IN
R
DC 12 V
(Alarm output equivalent circuit)
Grounding
terminal
GND
Caution
Connect the VN-C655 grounding terminal
to the one of the annunciator.