7. Using an adjustable wrench and a 1/2" (1.3 cm) open end wrench remove the Propane (L) orifice spud and replace with the correct Natural Gas (NG) orifice spud. See Natural Gas Orifice Spud Chart. 10. Check that the control console is flush with the top edge of the range. Use 1/2" (1.3 cm) open end wrench to remove/replace orifice Hold with adjustable wrench here 8. Reposition the grill orifice holder assembly back into the burner box, and replace the grill orifice holder bracket and two holder screws. 9. Lift up on the control console and set it back into place. For a proper fit, the flange of the control console must hook over the lip on the front of the range cooktop. NOTE: It may be necessary to lift valve stems to align with console holes. A A. Flush with range top 11. Replace the screws on each side of the control console. 12. Replace the control knobs and bezels. 13. Replace burner grates. Complete Installation 1. Refer to the "Make Gas Connection" section for properly connecting the range to the gas supply. 2. Refer to the "Electronic Ignition System" section for proper burner ignition, operation, and burner flame adjustments. IMPORTANT: You may have to adjust the "LO" setting for each range burner. Checking for proper range burner flame is very important. The small inner cone should have a very distinct blue flame 1/4" (6.4 mm) to 1/2" (1.3 cm) long. The outer cone is not as distinct as the inner cone. Propane gas flames have a slightly yellow tip. 3. Refer to "Complete Installation" in the "Installation Instructions" section of this manual to complete this procedure. A B A. Control console flange B. Front lip of range cooktop 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

23
7.
Using an adjustable wrench and a 1/2" (1.3 cm) open end
wrench remove the Propane (L) orifice spud and replace with
the correct Natural Gas (NG) orifice spud. See Natural Gas
Orifice Spud Chart.
8.
Reposition the grill orifice holder assembly back into the
burner box, and replace the grill orifice holder bracket and
two holder screws.
9.
Lift up on the control console and set it back into place. For
a proper fit, the flange of the control console must hook over
the lip on the front of the range cooktop.
NOTE:
It may be necessary to lift valve stems to align with
console holes.
10.
Check that the control console is flush with the top edge of
the range.
11.
Replace the screws on each side of the control console.
12.
Replace the control knobs and bezels.
13.
Replace burner grates.
Complete Installation
1.
Refer to the “Make Gas Connection” section for properly
connecting the range to the gas supply.
2.
Refer to the “Electronic Ignition System” section for proper
burner ignition, operation, and burner flame adjustments.
IMPORTANT:
You may have to adjust the “LO” setting for
each range burner.
Checking for proper range burner flame is very important.
The small inner cone should have a very distinct blue flame
1/4" (6.4 mm) to 1/2" (1.3 cm) long. The outer cone is not as
distinct as the inner cone. Propane gas flames have a slightly
yellow tip.
3.
Refer to “Complete Installation” in the “Installation
Instructions” section of this manual to complete this
procedure.
Use
1
/2
"
(1.3 cm)
open end wrench
to remove/replace
orifice
Hold with adjustable
wrench here
A
B
A. Control console flange
B. Front lip of range cooktop
A
A. Flush with range top