Kyocera FS C5020N FS-C5020/C5030 Operation Guide (Advanced Edition) - Page 135

RS-232C Protocol, Parameters of the RS-232C Protocol, H1: Baud rate, H2: Number of data bits

Page 135 highlights

Computer Interface RS-232C Protocol Parameters of the RS-232C Protocol A protocol is a set of rules followed by various devices to send or receive data. The parameters of the RS-232C protocol are stored in the batterypowered memory of the printer. You can verify these parameters on the status printout as marked by the following identifications: • H1: Baud rate • H2: Number of data bits • H3: Number of stop bits • H4: Parity • H5: Protocol logic • H6: Buffer-nearly-full threshold • H7: Buffer nearly-empty threshold • H8: Received data buffer size The parameters can be changed from the printer operator panel. To change the value for the serial interface parameters, see Changing Serial Interface Parameters on page 2-30. This following section outlines the parameters and their values you can select on the operator panel: H1: Baud rate Parameter value 12 24 48 96 19 38 57 11 Baud rate 1200 2400 4800 9600 19200 38400 57600 115200 The factory setting is 96 (9600 baud). H2: Number of data bits 7 or 8. The factory setting is 8. H3: Number of stop bits 1 or 2. The factory setting is 1. ADVANCED OPERATION GUIDE 4-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150

Computer Interface
ADVANCED OPERATION GUIDE
4-7
RS-232C Protocol
Parameters of the RS-232C Protocol
A protocol is a set of rules followed by various devices to send or receive
data. The parameters of the RS-232C protocol are stored in the battery-
powered memory of the printer. You can verify these parameters on the
status printout as marked by the following identifications:
H1: Baud rate
H2: Number of data bits
H3: Number of stop bits
H4: Parity
H5: Protocol logic
H6: Buffer-nearly-full threshold
H7: Buffer nearly-empty threshold
H8: Received data buffer size
The parameters can be changed from the printer operator panel. To
change the value for the serial interface parameters, see
Changing Serial
Interface Parameters on page 2-30
.
This following section outlines the parameters and their values you can
select on the operator panel:
H1: Baud rate
The factory setting is 96 (9600 baud).
H2: Number of data bits
7 or 8. The factory setting is 8.
H3: Number of stop bits
1 or 2. The factory setting is 1.
Parameter value
Baud rate
12
1200
24
2400
48
4800
96
9600
19
19200
38
38400
57
57600
11