7) TEMPERATURE COMPENSATION FREEZER TEMPERATURE COMPENSATION IC1 FREEZER ROOM RESISTANCE VALUES(R1) TEMPERATURE COMPENSATION 180 k_ + 5.0°C 56 k_ +4.0°C 33 k_ +3.0°C 18 k_ +2.0°C 12 k_ +1.0°C 10 k_ O°C 8.2 k_ -1.O°C 5.6 k_) -2.0°C 3.3 k_) _3.0°C 2 k£_ 4.0°C 470 £_ _5.0oc REMARKS COMPENSATE WARMLY J STANDARD COMPENSATE COOLLY • TEMPERATURE COMPENSATION TABLE by adjusting resistance values. (the temp difference compared to the present temp,) eg) If the compensation resistance of freezer compartment is changed from 10K (present resistance) to 18K (revised resistance), the temp of freezer compartment goes up by +2°C. - 25 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

7) TEMPERATURE
COMPENSATION
FREEZER
TEMPERATURE
COMPENSATION
IC1
FREEZER
ROOM
RESISTANCE
VALUES(R1)
180 k_
56 k_
33 k_
18 k_
12 k_
10 k_
8.2 k_
5.6 k_)
3.3 k_)
2 k£_
470 £_
TEMPERATURE
COMPENSATION
+ 5.0°C
+4.0°C
+3.0°C
+2.0°C
+1.0°C
O°C
-1.O°C
-2.0°C
_3.0°C
4.0°C
_5.0oc
REMARKS
COMPENSATE
WARMLY
J
STANDARD
COMPENSATE COOLLY
TEMPERATURE
COMPENSATION
TABLE by adjusting
resistance
values. (the temp difference
compared
to the present
temp,)
eg) If the compensation
resistance
of freezer
compartment
is changed from
10K (present resistance)
to 18K (revised
resistance),
the temp of freezer
compartment
goes up by +2°C.
- 25 -