TROUBLESHOOTING, Mechanical - replacement parts
UPC - 048231777223
View all LG LRBP1031W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
TROUBLESHOOTING (Mechanical Part) 1 COMPRESSOR AND ELECTRIC COMPONENTS SPoouwrecer . Remove the PTC]_ Starter from the Compressor and measure the voltage between Terminal C of Compressor and Terminals 5 or 6 of PTC. (Rating Voltage _+10%)? YES _ OLP disconnected? YES Replace OLR in the range of Rating }Dj AVpopltaliegde v_o+l1ta0g%e. isn't Check the resistance of Motor Compressor. _ among M-C, S-C and M-S in Motor Cohmecpkretshseor.resistance Advise the customer _ to use a regular Trans. condition. CRheeccoknnceocnt.nection YES Replace Compressor. Check the resistance of two terminals in PTC- PTC-Starter. _I Sthaertcekr. the resistance of YES NO _- I RPTepCl-aSctearter. Check OLR _ a hreegcuklairf aOppLlPy.ing YES 30 sec. in forcible OLP operation by OtounLrnPainngwdoiornkfsfs.tanwtithpinower b Replace OLP. YES Csthaertcinkg state. starting voltage after 5 min. for balancing cycle _,_ preesassuurree PTC. manindimcouomling the _ the voltage of Rating Voltage -+10% below. ComponentsI start in O_K_ NO -11 -