k][z][ ][Set ID][ ][Data][Cr], z][ ][Set ID][ ][OK][Data][x], Data FF : Read
View all LG M3204CCBA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
RS-232C Controlling Multiple Set Transmission / Receiving Protocol 16. Abnormal state (Command : z) ► Abnormal State : Used to Read the power off status when Stand-by mode. Transmission [k][z][ ][Set ID][ ][Data][Cr] Data FF : Read Acknowledgement [z][ ][Set ID][ ][OK][Data][x] 0 : Normal (Power on and signal exist) 1 : No signal (Power on) 2 : Turn the monitor off by remote control 3 : Turn the monitor off by sleep time function 4 : Turn the monitor off by RS-232C function 8 : Turn the monitor off by off time function 9 : Turn the monitor off by auto off function 17. ISM mode(Command: j p) ► Used to select the afterimage preventing function. Transmission [j][p][ ][Set ID][ ][Data][Cr] Data 1H : Inversion 2H : Orbiter 4H : White Wash 8H : Normal Acknowledgement [p][ ][Set ID][ ][OK][Data][x] A12