Lenovo ThinkPad i Series 172x ThinkPad 390 / i Series 1720 models Hardware Mai - Page 44

Error Messages

Page 44 highlights

Symptom/Error 02B2 Incorrect Drive A type - run SETUP 02D0 System cache error - Cache disabled 02F0 CPU ID: 02F5 DMA Test Failed 02F6 Software NMI Failed 02F7 Fail-Safe Timer NMI Failed FRU/Action in Sequence 1. Check that the drive is defined with the proper diskette type in BIOS Setup Utility. 2. Go to "Diskette Drive Checkout" on page 25. 1. CPU card 2. Planar board 1. CPU card 2. Planar board 1. DIMM 2. CPU card 3. Planar board 1. DIMM 2. CPU card 3. Planar board 1. DIMM 2. CPU card 3. Planar board Error Messages Symptom/Error Device Address Conflict Allocation Error for: device Failing Bits: nnnn Invalid System Configuration Data I/O device IRQ conflict FRU/Action in Sequence 1. Load Setup Defaults in BIOS Setup Utility. 2. Backup battery (RTC) 3. Planar board 1. Load Setup Defaults in BIOS Setup Utility. 2. Backup battery (RTC) 3. Planar board 1. DIMM 2. BIOS ROM 3. Planar board 1. BIOS ROM 2. Planar board 1. Load Setup Defaults in BIOS Setup Utility. 2. Backup battery (RTC) 3. Planar board 36 ThinkPad 390/i Series 1700

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101

Symptom/Error
FRU/Action in Sequence
02B2
Incorrect
Drive A type
— run
SETUP
1.
Check that the drive is defined with
the proper diskette type in BIOS
Setup Utility.
2.
Go to “Diskette Drive Checkout” on
page 25.
02D0
System
cache error
— Cache dis-
abled
1.
CPU card
2.
Planar board
02F0
CPU ID:
1.
CPU card
2.
Planar board
02F5
DMA Test
Failed
1.
DIMM
2.
CPU card
3.
Planar board
02F6
Software NMI
Failed
1.
DIMM
2.
CPU card
3.
Planar board
02F7
Fail-Safe
Timer NMI
Failed
1.
DIMM
2.
CPU card
3.
Planar board
Error Messages
Symptom/Error
FRU/Action in Sequence
Device
Address Con-
flict
1.
Load Setup Defaults in BIOS Setup
Utility.
2.
Backup battery (RTC)
3.
Planar board
Allocation
Error for:
device
1.
Load Setup Defaults in BIOS Setup
Utility.
2.
Backup battery (RTC)
3.
Planar board
Failing Bits:
nnnn
1.
DIMM
2.
BIOS ROM
3.
Planar board
Invalid
System Con-
figuration
Data
1.
BIOS ROM
2.
Planar board
I/O device
IRQ conflict
1.
Load Setup Defaults in BIOS Setup
Utility.
2.
Backup battery (RTC)
3.
Planar board
36