Lexmark E260 Service Manual - Page 69

Service error codes 9, Continued

Page 69 highlights

Service error codes (9xx) (Continued) 4513-200, -220, -230 Error Description Action 922.05 Did not roll over to a steady state control in time after the Replace the fuser. See "Fuser service check" hot roll lamp detection. on page 2-53. 922.06 Hot roll did not reach the operating temperature in time (new enhanced control). 922.07 Media reached fuser nip, and fuser is under temperature 922.08 Fuser warm-up failure (motor start condition) 922.09 Fuser warm-up failure (compression set) 922.20 Belt fuser failed to reach the preheat temperature for the motor to start during warm-up. 922.21 Belt fuser was under temperature when the media reached the fuser nip. 923.00 Fuser is over temperature. 923.01 Fuser is over temperature. This applies to the fuser and belt fusers. 924.00 Open thermistor check. 924.01 Open thermistor check failure. This applies to the fuser and belt fusers. 924.02 Open thermistor check failure. The ADC failed to converge. Possible noisy thermistor signal. This applies to the fuser and belt fusers. 925.xx Wrong fuser installed. The fuser type stored in the cartridge ID does not match the actual fuser installed in the printer. Fan service errors 927.00 927.03 Service fan error Main fan took too long to ramp up Replace the fan. See "Cooling fan service check" on page 2-52. 927.04 Main fan is under speed or stalled during speed adjustment state 927.05 Main fan overspeed during speed adjustment state. 927.06 Main fan capture data is invalid, and speed control is at maximum in fan control idle state 927.07 Main fan capture data is invalid, and speed control is at maximum in fan control adjustment state. Printhead service errors 930.00 931.00 Wrong printhead installed No first hsync Replace the printhead. See "Printhead service check" on page 2-65. Diagnostics information 2-43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

Diagnostics information
2-43
4513-200, -220, -230
922.05
Did not roll over to a steady state control in time after the
hot roll lamp detection.
Replace the fuser. See
“Fuser service check”
on page 2-53
.
922.06
Hot roll did not reach the operating temperature in time
(new enhanced control).
922.07
Media reached fuser nip, and fuser is under temperature
922.08
Fuser warm-up failure (motor start condition)
922.09
Fuser warm-up failure (compression set)
922.20
Belt fuser failed to reach the preheat temperature for the
motor to start during warm-up.
922.21
Belt fuser was under temperature when the media
reached the fuser nip.
923.00
Fuser is over temperature.
923.01
Fuser is over temperature. This applies to the fuser and
belt fusers.
924.00
Open thermistor check.
924.01
Open thermistor check failure. This applies to the fuser
and belt fusers.
924.02
Open thermistor check failure. The ADC failed to
converge. Possible noisy thermistor signal. This applies
to the fuser and belt fusers.
925.xx
Wrong fuser installed. The fuser type stored in the
cartridge ID does not match the actual fuser installed in
the printer.
Fan service errors
927.00
Service fan error
Replace the fan. See
“Cooling fan service
check” on page 2-52
.
927.03
Main fan took too long to ramp up
927.04
Main fan is under speed or stalled during speed
adjustment state
927.05
Main fan overspeed during speed adjustment state.
927.06
Main fan capture data is invalid, and speed control is at
maximum in fan control idle state
927.07
Main fan capture data is invalid, and speed control is at
maximum in fan control adjustment state.
Printhead service errors
930.00
Wrong printhead installed
Replace the printhead. See
“Printhead service
check” on page 2-65
.
931.00
No first hsync
Service error codes (9
xx
) (Continued)
Error
Description
Action