LiftMaster ATS ATS2113X Manual - Page 25
Using the Wall-Mounted Door Control, To Open the Door Manually
View all LiftMaster ATS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
Using the Wall-Mounted Door Control Press the push button to open or close the door. Press again to reverse the door during the closing cycle or to stop the door while it's opening. To Open the Door Manually To prevent possible SERIOUS INJURY or DEATH from a falling garage door: • If possible, use emergency release handle to disengage trolley ONLY when garage door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/ or unexpectedly. • NEVER use emergency release handle unless garage doorway is clear of persons and obstructions. • NEVER use handle to pull door open or closed. If rope knot becomes untied, you could fall. The door should be fully closed if possible. Pull down on the emergency release handle and lift the Emergency door manually. To reconnect the door Release to the opener, press the door control Handle Trolley Release Arm push bar. (Pull Down) MANUAL DISCONNECT POSITION The lockout feature prevents the trolley from reconnecting automatically. Pull the emergency release handle down and back (toward the opener). The door can then be raised and lowered manually Emergency Trolley Release Arm as often as necessary. To disengage the lockout feature, pull the handle straight down. The trolley will Release Handle (Down and Back) reconnect on the next UP or DOWN LOCKOUT POSITION operation. 25