LiftMaster ATS ATS2113X Manual - Page 26

Care Of Your Opener - rail

Page 26 highlights

CARE OF YOUR OPENER LIMIT AND FORCE ADJUSTMENTS: FORCE CONTROLS Weather conditions may cause some minor changes in door operation requiring some re-adjustments, particularly during the first year of operation. LIMIT CONTROLS Pages 21 and 22 refer to the limit and force adjustments. Only a screwdriver is required. Follow the instructions carefully. Repeat the safety reverse test (Adjustment Step 3, page 23) after any adjustment of limits or force. MAINTENANCE SCHEDULE Every Month • Manually operate door. If it is unbalanced or binding, call a trained door systems technician. • Check to be sure door opens and closes fully. Adjust limits and/or force if necessary. (See pages 21 and 22.) • Repeat the safety reverse test. Make any necessary adjustments. (See Adjustment Step 3.) Two Times a Year • Check chain tension. Disconnect trolley first. Adjust if necessary. (See page 7.) Every Year • Oil door rollers, bearings and hinges. The opener does not require additional lubrication. Do not grease the door tracks. Every Three to Four Years • Use a rag to wipe away the existing grease from the garage door opener rail. Reapply a small layer of white lithium grease to the rail. THE REMOTE CONTROL BATTERIES To prevent possible SERIOUS INJURY or DEATH: • NEVER allow small children near batteries. • If battery is swallowed, immediately notify doctor. To reduce risk of fire, explosion or chemical burn: • Replace ONLY with 3V2032 coin batteries. • DO NOT recharge, disassemble, heat above 100° C (212° F) or incinerate. The lithium battery should produce power for up to 5 years. To replace battery, use the visor clip or screwdriver blade to pry open the case as shown. Insert battery positive side up (+). Dispose of old battery properly. Replace the battery with only 3V2032 coin cell batteries. Battery positive side up (+) NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

26
CARE OF YOUR OPENER
LIMIT AND FORCE ADJUSTMENTS:
Weather conditions may cause some
minor changes in door operation
requiring some re-adjustments,
particularly during the first year of
operation.
Pages 21 and 22 refer to the limit and
force adjustments. Only a screwdriver is required. Follow
the instructions carefully.
Repeat the safety reverse test (Adjustment Step 3,
page 23) after any adjustment of limits or force.
MAINTENANCE SCHEDULE
Every Month
Manually operate door. If it is unbalanced or binding,
call a trained door systems technician.
Check to be sure door opens and closes fully. Adjust
limits and/or force if necessary. (See pages 21 and 22.)
Repeat the safety reverse test. Make any necessary
adjustments. (See Adjustment Step 3.)
Two Times a Year
Check chain tension. Disconnect trolley first. Adjust if
necessary. (See page 7.)
Every Year
Oil door rollers, bearings and hinges. The opener does
not require additional lubrication. Do not grease the
door tracks.
Every Three to Four Years
Use a rag to wipe away the existing grease from the
garage door opener rail. Reapply a small layer of white
lithium grease to the rail.
FORCE CONTROLS
LIMIT CONTROLS
NOTICE: To comply with FCC and or Industry Canada (IC) rules,
adjustment or modifications of this receiver and/or transmitter are
prohibited, except for changing the code setting or replacing the
battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE.
Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation.
The lithium battery should produce power for
up to 5 years.
To replace battery, use the
visor clip or screwdriver
blade to pry open the case as
shown. Insert battery positive
side up (+).
Dispose of old battery
properly.
Replace the battery with only
3V2032 coin cell batteries.
Battery
positive
side up (+)
THE REMOTE CONTROL BATTERIES
To prevent possible SERIOUS INJURY or DEATH:
NEVER allow small children near batteries.
• If battery is swallowed, immediately notify doctor.
To reduce risk of fire, explosion or chemical burn:
Replace ONLY with 3V2032 coin batteries.
DO NOT recharge, disassemble, heat above 100° C
(212° F) or incinerate.